PRODUCT SKU : IC660BBA025

PRODUCT TYPE : Analog Output Module

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview:
The IC660BBA025 from GE Fanuc is a high-precision, software-configurable analog output module designed for industrial automation. Supporting six independent 4–20mA output circuits, it delivers reliable current-source control without requiring manual calibration. The module integrates advanced diagnostic functions and supports bus switching module control, ensuring robust operation in distributed control systems.

Key Features:

  • Six 4–20mA analog output channels, configurable via software

  • No calibration required for operation

  • Built-in diagnostic capabilities including output overrange, underrange, and feedback verification

  • Bus Switching Module support for coordinated control

  • Provides power to all circuits; separate power supply for 4–20mA signals is not necessary

  • Circuit-level configurability: hold last state, default state, or scale to engineering units

  • High output accuracy of 0.15% at 25°C with 6μA resolution

  • Supports CPU redundancy and per-channel fault reporting

Technical Specifications:

  • Model Number: IC660BBA025

  • Output Channels: 6, 4–20mA current source

  • Power Supply: 24–48 VDC nominal, 18–56 VDC range

  • Maximum Current: 600 mA

  • Frequency/Ripple: Maximum 10%

  • Block Isolation: 1500V for 1 minute

  • Heat Dissipation: 12 W max

  • Dimensions: 8.83" × 3.34" × 3.91" (22.44 × 8.48 × 9.93 cm)

  • Weight: 4 lbs (1.8 kg)

  • LED Indicators: Unit OK, I/O Enabled

  • Output Accuracy: ±0.15% at 25°C

  • Output Resolution: 6 μA

Applications:
Ideal for use in process control, machine automation, and distributed control systems, IC660BBA025 provides precise current output for industrial controllers where reliability and diagnostic feedback are critical.

FAQ:
Q: Is this module factory-new and original?
A: Yes, all units are original GE Fanuc products.

Q: Does it require external calibration?
A: No, calibration is not required; outputs are ready to use out-of-the-box.

Q: What is the shipping time?
A: Inventory is ready for shipment, typically within 3–10 business days depending on quantity.

Q: Can I monitor faults for each channel individually?
A: Yes, fault reporting can be enabled or disabled per channel.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more
Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Proper wire labeling forms the cornerstone of reliable control system installation and long-term maintenance. In complex industrial automation environments, technicians terminate thousands of conductor ends inside control panels, marshalling racks, and field junction boxes. Ferrules serve as individual tube-shaped sleeve markers slipped onto conductors before final termination. While technicians historically relied on pre-printed individual letter rings, modern control panel builders utilize automated ferrule printing machines. These thermal-transfer printers generate durable, single-sleeve heat-shrink tags directly matching approved wiring schematics, significantly accelerating cabinet assembly workflows.

Read more