PRODUCT SKU : IC200MDL744

PRODUCT TYPE : Discrete Output Module

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The GE Fanuc VersaMax IC200MDL744 is discrete output modules designed for VersaMax PLC systems. They provide 32 output points divided into two groups, supporting multiple DC voltage ranges for flexible control applications. With robust isolation between groups, LED indicators for each channel, and high current capacity, these modules deliver reliable performance in demanding automation environments.

Technical Specifications

  • Manufacturer: GE Fanuc Emerson

  • Model / Part Number: IC200MDL744

  • Product Line: VersaMax

  • Product Type: Discrete Output Module

  • Weight: 1.00 lbs (0.45 kg)

  • Number of Outputs: 32 points, organized into 2 groups

  • Output Voltage Ranges:

    • TTL mode: 4.75–5.25 VDC (nominal 5 VDC)

    • Standard mode: 10.2–30 VDC (nominal 12/24 VDC)

  • Output Current Capacity: Up to 5 A per point

  • Group-to-Group Isolation: 250 VAC continuous, 1500 VAC for 1 minute

  • Point-to-Point Isolation: None

  • Indicators: One LED per output, plus OK and FLD PWR LEDs

  • Backplane Current Consumption: 140 mA at 5 VDC

  • Protection: No internal fuse (external protection required)

  • Module ID: 80808080

Application Scenarios

The IC200MDL744 is suitable for machine control, process automation, and distributed I/O systems requiring multiple DC outputs. Its dual voltage support makes it versatile for applications involving mixed signal levels.

FAQ

Q: How many outputs does the IC200MDL744 provide?  A: It offers 32 discrete outputs divided into two groups.

Q: What isolation is provided?  A: Group-to-group isolation is rated at 250 VAC continuous and 1500 VAC for one minute.

Q: Does the module include internal fuses?  A: No, external protection must be provided.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more