PRODUCT SKU : UR6BH

PRODUCT TYPE : Digital I/O Module

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview  

The GE UR6BH Digital I/O Card is part of the Multilin Universal Relay (UR) series, engineered for industrial control and protection systems. It provides 16 isolated digital input/output channels, enabling precise monitoring, fast logic operations, and reliable integration into modern grid and industrial automation environments.

Technical Specifications

  • Manufacturer: General Electric (GE)

  • Model: UR6BH

  • Type: Digital I/O Module

  • Series: Universal Relay (UR) Series

  • Channels: 16 isolated digital I/O channels

  • Input Voltage: 24 V DC

  • Output Voltage: 24 V DC

  • Dimensions: 280 mm × 115 mm × 45 mm

  • Weight: 0.6 kg

  • Protection Functions: Undervoltage, overvoltage, breaker failure detection

  • Logic Capability: High-speed trip and close operations

  • Metering Accuracy: High precision for industrial applications

  • Communication: Compatible with multiple protocols for system integration

  • Packaging: Supplied in original factory-sealed condition

Key Features

  • Sixteen isolated digital channels for reliable input/output operations

  • High-speed logic for rapid trip and close functions

  • Integrated protection features including undervoltage and breaker failure detection

  • Accurate metering for industrial-grade monitoring

  • Flexible communication protocol support for seamless integration

Applications

  • Power system protection and control

  • Substation automation requiring digital I/O expansion

  • Industrial automation systems with high-speed logic requirements

  • Integration into modern grid systems with multi-protocol communication

FAQ

  • Q: How many channels does the UR6BH provide?  A: It offers 16 isolated digital input/output channels.

  • Q: What protection functions are supported?  A: The module includes undervoltage, overvoltage, and breaker failure detection.

  • Q: Is the UR6BH compatible with other UR series modules?  A: Yes, it integrates seamlessly with the GE Multilin UR series.

 

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Preventing Spurious Trips in Emergency Stop Systems: A Technical Guide

Preventing Spurious Trips in Emergency Stop Systems: A Technical Guide

In industrial automation, the Emergency Stop (E-Stop) pushbutton is the ultimate safety line. However, relying on a single Normally-Closed (NC) contact can sometimes lead to unexpected spurious trips. As a control systems engineer, I have seen these nuisance trips halt entire production lines, causing significant downtime. Understanding why these components fail and how to implement robust architecture is essential for any reliable DCS or PLC-based safety system.

Read more
Sequencing Induction Motor Control with PLC Logic: Best Practices

Sequencing Induction Motor Control with PLC Logic: Best Practices

In modern industrial automation, controlling a group of induction motors requires precision and safety. Uncontrolled simultaneous startup of multiple large motors often causes significant voltage dips, potentially triggering protective trips. Therefore, implementing a sequential startup and shutdown strategy is essential. This approach minimizes inrush current and ensures the system operates within established power constraints. A robust PLC program serves as the ideal engine for orchestrating these sequences.

Read more
Mastering PLC Programming: Best Practices for Robust Industrial Automation

Mastering PLC Programming: Best Practices for Robust Industrial Automation

Writing clean PLC code requires discipline, especially regarding memory management. Avoid overusing SET and RESET instructions, as they often complicate debugging. If multiple rungs control the same bit, troubleshooting becomes a nightmare. Instead, focus on energizing a bit in only one location. If your logic requires complex conditions, use branches within a single rung. This approach keeps your code readable, maintainable, and significantly easier to audit during downtime.

Read more