Skip to content

What are you looking for?


You may also like

FLEX I/O Digital DC Input Module 1794-IB16D by Allen-BradleyFLEX I/O Digital DC Input Module 1794-IB16D by Allen-BradleyFLEX I/O Digital DC Input Module 1794-IB16D by Allen-Bradley
FLEX I/O Digital DC Input Module 1794-IB16D by Allen-Bradley
FLEX I/O Digital DC Input Module 1794-IB16D by Allen-Bradley
FLEX I/O Digital DC Input Module 1794-IB16D by Allen-Bradley

FLEX I/O Digital DC Input Module 1794-IB16D by Allen-Bradley


Only 10 left - Selling fast

PRODUCT SKU : 1794-IB16D

PRODUCT TYPE : Digital DC Input Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview
The Allen-Bradley 1794-IB16D is a high-performance FLEX I/O digital input module providing 16 current sinking DC inputs with integrated diagnostic indicators. Designed for modular control networks, this module delivers precise signal monitoring, rapid fault detection, and reliable system integration.

Technical Specifications

  • Manufacturer: Allen-Bradley

  • Model / Part Number: 1794-IB16D

  • Product Type: FLEX Digital DC Input Module with Diagnostics

  • Number of Inputs: 16, current sinking

  • Recommended Terminal Bases: 1794-TB32, 1794-TB32S, 1794-TB62DS, 1794-TB62EXD4X15

  • Nominal Input Impedance: 3.1 kΩ

  • Isolation Voltage: 50 V continuous, Basic insulation; type tested at 2121 V DC for 2 s between field side and system

  • Channel Isolation: No isolation between individual channels

  • FlexBus Current: 30 mA @ 5 V DC

  • Max Power Dissipation: 8.5 W @ 31.2 V DC

  • Max Thermal Dissipation: 29 BTU/hr @ 31.2 V DC

  • Sensor Power: Max 2.2 V voltage drop, 50 mA current

  • Field Indicators: 16 yellow ON/OFF LEDs, 16 red diagnostic LEDs, 1 red module fault LED

  • Dimensions (HxWxD): 4.57 × 9.4 × 5.33 cm

  • Shipping Weight: 1.5 kg

  • Operating Temperature: Standard FLEX I/O range (-20°C to 70°C typical)

Applications
Suitable for distributed digital input collection in modular control systems, process monitoring, and machine automation. The diagnostic LEDs provide real-time status and fault detection, reducing maintenance time and improving system reliability.

FAQ
Q: How many input channels does 1794-IB16D provide?
A: The module has 16 sinking DC input channels.

Q: Does it provide diagnostics for each channel?
A: Yes, it features 16 yellow status indicators, 16 red diagnostic indicators, and 1 module fault indicator.

Q: Which terminal bases are compatible with this module?
A: Compatible with 1794-TB32, 1794-TB32S, 1794-TB62DS, and 1794-TB62EXD4X15.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Engineering MCC Signal Interface Terminations in Modern Process Automation

Engineering MCC Signal Interface Terminations in Modern Process Automation

Industrial manufacturing plants rely on Motor Control Centers (MCC) to drive critical electrical loads. Plant engineers must interface these MCC motor starters and drives with central control systems. Standardizing the Signal Interface Termination (SIT) architecture ensures seamless command delivery and feedback monitoring between field equipment and process automation platforms.

Read more
Layer-2 vs. Layer-3 Network Switches in Industrial Control Systems

Layer-2 vs. Layer-3 Network Switches in Industrial Control Systems

Modern factory automation relies heavily on robust Industrial Ethernet communications. Control system engineers deploy managed Ethernet switches to connect programmable logic controllers (PLCs), distributed control systems (DCS), human-machine interfaces (HMIs), and field I/O devices. Selecting between Layer-2 and Layer-3 switching architecture directly impacts network throughput, routing capabilities, and overall cybersecurity defense in operational technology (OT) networks.

Read more
Understanding OpenTelemetry in Industrial Automation: Architecture, Observability, and Operational Benefits

Understanding OpenTelemetry in Industrial Automation: Architecture, Observability, and Operational Benefits

Modern industrial control systems (PLCs, DCS, edge nodes) are rapidly adopting cloud-native architectures, generating vast operational data. OpenTelemetry offers an open-source framework that unifies metrics, logs, and execution traces, enabling standardized observability across industrial automation and IT systems.

Read more