Skip to content

What are you looking for?


You may also like

Emerson KJ3225X1-BA1 DeltaV RTD/Resistance Input CardEmerson KJ3225X1-BA1 DeltaV RTD/Resistance Input CardEmerson KJ3225X1-BA1 DeltaV RTD/Resistance Input Card
Emerson KJ3225X1-BA1 DeltaV RTD/Resistance Input Card
Emerson KJ3225X1-BA1 DeltaV RTD/Resistance Input Card
Emerson KJ3225X1-BA1 DeltaV RTD/Resistance Input Card

Emerson KJ3225X1-BA1 DeltaV RTD/Resistance Input Card


Only 10 left - Selling fast

PRODUCT SKU : KJ3225X1-BA1

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : EMERSON


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Emerson KJ3225X1-BA1, also cataloged as the KJ3225X1-BA1 RTD/Resistance Input Card, operates as a dedicated hardware component for low-voltage resistance signal acquisition within DeltaV electronic marshalling subsystems. This unit interfaces directly with resistance temperature detectors (RTDs) and ohmic instruments located in hazardous environments, executing direct down-loop signal conditioning and digitizing physical temperatures into process data blocks over the system backplane network.

Hardware Specifications

Parameter Specification
Model KJ3225X1-BA1
Brand Emerson
Origin USA
Weight 0.20 kg
Dimensions Standard DeltaV I/O module footprint profile
Operating Temp -40 deg C to +70 deg C
Power Consumption 12 VDC at 160 mA (Local Bus Power)
Input Channel Count Multi-channel RTD / Resistance inputs
Shock Resistance 10g 1/2 sine wave for 11 ms
Vibration Resistance 1 mm peak-to-peak from 2 to 13.2 Hz; 0.7g from 13.2 to 150 Hz
Airborne Contaminants ISA-S71.04 Class G3 compliance
Relative Humidity 5% to 95% non-condensing
Hazardous Certification ATEX certified for hazardous atmospheres

Channel-To-Channel Isolation and RTD Processing

Mechanical execution of this baseplate-mounted component relies on galvanic separation barriers to maintain thermal measurement reliability. The module architecture features high-precision analog-to-digital conversion parameters linked with active channel-to-channel isolation. This electrical boundary safeguards the sensitive measurement circuitry, ensuring that ground fault currents, common-mode noise, or localized voltage transients on an active field RTD wiring track cannot distort data values or introduce resistance offsets on neighboring signal channels.

Frequently Asked Questions

Q: Does this RTD input module support live hot-swap procedures while under bus power?

A: Yes. The hardware is designed for real-time hot-swap insertion and removal within an energized DeltaV carrier slot. Internal current-limiting circuits suppress electrical backplane bus disturbances, preventing diagnostic faults or communications interference on adjacent active cards.

Q: How does the integrated isolation protect against field wiring short circuits?

A: The embedded channel-to-channel isolation encapsulates any electrical fault or grounding failure on an individual field loop, preventing the localized failure from propagating to neighboring channels or affecting master controller processing operations.

Field Installation Guidelines

  • Baseplate Slot Insertion: Align the rear terminal guides of the module perpendicularly with the designated carrier receptor. Press downward firmly until the mechanical retention latches click completely into place to ensure uniform electrical tracking.

  • Hazardous Area Separation: All low-voltage sensor cables originating from hazardous areas must comply with ATEX certification boundaries. Maintain a minimum spatial distance of 50 mm between intrinsically safe field paths and standard non-intrinsically safe infrastructure inside the routing tracks.

  • Shield Ground Maintenance: Terminate RTD extension wire shields exclusively at the carrier grounding bar assembly. Implementing a strict single-point grounding layout prevents low-frequency circulating loops or common-mode noise from corrupting resistance data blocks.

  • Environmental Control Parameters: For deployment in sites matching Class G3 airborne contaminant profiles, the marshalling enclosure must maintain a continuous positive-pressure air flow and keep relative humidity below the 95% non-condensing limit to prevent terminal contact oxidation.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety relays form the bedrock of functional safety in modern factory automation, preventing catastrophic equipment failure and protecting plant personnel. While standard electromechanical relays handle basic load switching, they lack the redundant diagnostics required for high-risk industrial environments. Modern industrial automation platforms—including programmable logic controllers (PLCs) and distributed control systems (DCS)—rely on specialized safety relays to monitor field devices and isolate hazards instantly.

Read more
Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Industrial automation integrates speech recognition, IIoT protocols, and NLP with PLCs and DCS to streamline operations. By leveraging advanced edge computing, engineers enable real-time, hands-free control—allowing personnel to manage smart factory processes safely away from hazardous equipment.

Read more
Modern Industrial Automation: Transforming Safety and Efficiency in Mining Operations

Modern Industrial Automation: Transforming Safety and Efficiency in Mining Operations

Industrial automation has evolved from a simple manufacturing tool into the operational backbone of high-risk sectors. Modern mining operations increasingly rely on advanced control systems, programmable logic controllers (PLCs), distributed control systems (DCS), and artificial intelligence to address deep-underground hazards. By replacing manual labor in high-risk zones, factory automation technologies protect personnel while significantly boosting operational throughput.

Read more