Skip to content

What are you looking for?


You may also like

Emerson Epro CON041+PR6423/004-030-CN Eddy Current Proximity Sensor SystemEmerson Epro CON041+PR6423/004-030-CN Eddy Current Proximity Sensor SystemEmerson Epro CON041+PR6423/004-030-CN Eddy Current Proximity Sensor System
Emerson Epro CON041+PR6423/004-030-CN Eddy Current Proximity Sensor System
Emerson Epro CON041+PR6423/004-030-CN Eddy Current Proximity Sensor System
Emerson Epro CON041+PR6423/004-030-CN Eddy Current Proximity Sensor System

Emerson Epro CON041+PR6423/004-030-CN Eddy Current Proximity Sensor System


Only 10 left - Selling fast

PRODUCT SKU : CON041+PR6423/004-030-CN

PRODUCT TYPE : Proximity Sensors

PRODUCT VENDOR : EMERSON


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for high-frequency shaft displacement acquisition in rotating machinery, the Emerson Epro CON041+PR6423/004-030-CN (PR6423/004-030-CN) Eddy Current Proximity Sensor System provides direct physical execution of dynamic and static signal conditioning.

Hardware Specifications

Parameter Specification
Model CON041+PR6423/004-030-CN
Brand Emerson Epro
Dimensions 65 mm case thread (Probe)
Operating Temp 0 deg C to 45 deg C (Calibrated range)
Power Consumption Not Specified

Mechanical Monitoring and TSI Integration

The PR6423 series utilizes eddy-current induction to measure the clearance between the probe tip and a metallic rotor. Successful rotor dynamics analysis requires accurate eddy-current probe scaling to ensure the transducer voltage output remains linearly proportional to shaft displacement. During commissioning, users must perform gap voltage validation, targeting a -10 VDC center point to ensure the signal remains within the linear dynamic range. To maintain high-fidelity waveform capture, the system utilizes effective cross-talk suppression by ensuring high-frequency coaxial cables are routed independently from electromagnetic noise sources, preventing interference with the detection of shaft eccentricity and orbital vibration patterns.

Frequently Asked Questions

Q: Can the 8.0 m coaxial cable be modified or field-terminated?

A: No. The CON041 and PR6423 system is factory-calibrated as a matched pair. Modifying the cable length or replacing the Lemo connector alters the system impedance and resonant frequency, leading to significant measurement inaccuracies.

Q: Is the system compatible with non-ferromagnetic shaft materials?

A: No. The incremental scale factor (ISF) of 8 V/mm is optimized for standard steel targets. Utilizing this sensor on non-ferromagnetic surfaces will result in a non-linear signal response and reduced measurement sensitivity.

Field Installation Guidelines

  1. Probe Mounting: Secure the sensor in a rigid, vibration-isolated bracket to ensure measured displacement is relative to the shaft and not the machine casing.
  2. Gap Adjustment: Use a calibrated feeler gauge to establish the nominal 0.5 mm air gap. Verify that the sensor tip is positioned to accommodate the full range of shaft thermal expansion and dynamic movement without mechanical contact.
  3. Grounding: Terminate cable shields at a dedicated instrument ground bus. Ensure the CON041 converter housing is properly grounded to mitigate common-mode noise and ground loops.
  4. Environment: Route signal cables through dedicated conduits, separated from high-voltage power lines and VFD output cabling, to prevent electromagnetic interference.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more