PRODUCT SKU : 5X00223G01

PRODUCT TYPE : Digital I/O Cards

PRODUCT VENDOR : EMERSON


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for discrete signal transmission in Ovation distributed control systems, the Emerson 5X00223G01 (5X00223G01 Digital Output Module) provides direct physical electrical execution for driving 16 independent load channels. The module utilizes a high-side sourced transistor architecture to manage 24 VDC control signals, directing discrete logic transitions to interposing relays, solenoid valves, and status indicators.

Hardware Specifications

Parameter Specification
Model 5X00223G01
Brand Emerson
Operating Temp -40 to 70 deg C
Power Consumption Not Specified
Channels 16 Independent Outputs
Current Rating 0.5 A per channel
Switching Latency 10 ms

4-20 mA HART Loop Protocol Connectivity

While the 5X00223G01 is a digital output module, its interface architecture aligns with the broader Ovation DCS integration standards, including support for HART loop protocol-capable diagnostics when applied in mixed I/O configurations. The module provides 500 VAC channel-to-channel and channel-to-backplane galvanic isolation to suppress field-side transients. This isolation is necessary to maintain signal integrity and prevent high-energy electromagnetic interference (EMI) or inductive flyback from solenoid coils and relays from propagating into the backplane logic.

Frequently Asked Questions (FAQ)

Q: Does the 5X00223G01 support hot-swapping during active system operation?

A: Yes, the module supports hot-swap functionality. Removal or insertion can be performed without interrupting power to the I/O rack or the main controller; however, ensure all output loads are in a de-energized or safe state before module replacement.

Q: How does the module handle inductive loads such as solenoid valves?

A: The module includes internal clamping circuitry designed to manage inductive flyback voltages. Ensure that external suppression is consistent with the module specifications to prolong transistor life during high-frequency switching operations.

Field Installation Guidelines

  1. Verify the module keying configuration matches the I/O base unit to prevent mechanical interference or incorrect pin alignment.
  2. Align the module with the chassis guide rails and push firmly until the locking mechanism engages, ensuring full contact with the backplane connectors.
  3. Terminate all output field wiring at the module terminal block, ensuring correct polarity for 24 VDC loads.
  4. Route output cabling away from high-voltage AC power lines to mitigate inductive coupling and maintain EMI compliance.
  5. Confirm the status of individual channel LEDs and the module health indicator post-installation to verify valid communication with the Ovation controller.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Demystifying the DDE Protocol in Legacy Industrial Automation Systems

Demystifying the DDE Protocol in Legacy Industrial Automation Systems

Modern control systems rely heavily on seamless interprocess communication to exchange operational data between software programs. Microsoft first introduced the Dynamic Data Exchange (DDE) protocol in 1987 to enable real-time data sharing. In factory automation, DDE served as an early bridge between control software and Windows desktop applications. Therefore, understanding DDE mechanics provides crucial insights into how legacy industrial networks established software-level connectivity.

Read more
Demystifying CPU Communication Ports in Siemens PLC Architectures

Demystifying CPU Communication Ports in Siemens PLC Architectures

Industrial automation relies heavily on robust data exchange between devices. Without seamless connectivity, field instruments, network switches, human-machine interfaces, and programmable logic controllers cannot coordinate effectively. Therefore, understanding the various CPU communication ports available in Siemens hardware ensures efficient factory automation design and seamless system integration.

Read more
Mastering the Siemens PLC Scan Cycle: How the CPU Executes Automation Programs

Mastering the Siemens PLC Scan Cycle: How the CPU Executes Automation Programs

Industrial automation relies heavily on programmable logic controllers (PLCs) to manage complex manufacturing processes. Many engineers dive straight into programming without mastering the underlying architecture. However, understanding how a PLC CPU executes a program ensures reliable system design. Therefore, mastering the scan cycle optimizes both performance and troubleshooting in modern control systems.

Read more