Skip to content

What are you looking for?


You may also like

Emerson 5X00058G01 Analog Input ModuleEmerson 5X00058G01 Analog Input ModuleEmerson 5X00058G01 Analog Input Module
Emerson 5X00058G01 Analog Input Module
Emerson 5X00058G01 Analog Input Module
Emerson 5X00058G01 Analog Input Module

Emerson 5X00058G01 Analog Input Module


Only 10 left - Selling fast

PRODUCT SKU : 5X00058G01

PRODUCT TYPE : Analog Input Modules

PRODUCT VENDOR : EMERSON


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for HART-enabled signal acquisition in Ovation process control systems, the Emerson 5X00058G01 (5X00058G01 Analog Input Module) provides direct physical execution of high-precision analog input monitoring and digital communication.

Hardware Specifications

Parameter Specification
Model 5X00058G01
Brand Emerson
Origin Manufacturer-defined
Weight 6.80 kg
Dimensions Standard Ovation module form factor
Operating Temp Industrial standard range
Power Consumption System-dependent load
Function HART-enabled Analog Input

4-20 mA HART Loop Protocol

The 5X00058G01 facilitates the acquisition of analog process variables while concurrently supporting the 4-20 mA HART loop protocol for device diagnostics and configuration. The module architecture ensures channel-to-channel isolation to protect the analog signal integrity from common-mode noise and ground loops in multi-channel configurations. Data conversion is performed to map the 4-20 mA input signal into a digital format suitable for controller processing. This integration allows for the seamless extraction of secondary variables and diagnostic data from field-mounted transmitters without disrupting the primary control loop.

Frequently Asked Questions

Q: Does the 5X00058G01 module support hot-swapping during active system operation?

A: The module is designed for hot-swap operations within the Ovation I/O rack. Before physical module removal, ensure that the corresponding I/O points are inhibited in the Ovation engineering software to prevent false process alarms or control interrupts.

Q: Are there limitations on the HART communication frequency supported by this module?

A: The module adheres to the HART protocol specification for data transmission superimposed on the analog signal. Verify that the field-side cabling and loop impedance are within the defined parameters for reliable HART communication to avoid packet loss during variable polling.

Field Installation Guidelines

  1. Verify that the I/O rack slot is prepared for installation and confirm the power to the module is inhibited if system policy mandates.
  2. Align the 5X00058G01 module with the backplane connectors and seat firmly to establish secure bus communication.
  3. Terminate signal conductors to the designated terminal block, ensuring proper wire gauge and polarity for all input channels.
  4. Utilize shielded twisted-pair cabling for all analog signal runs and ensure the cable shield is connected to the cabinet ground at a single point to mitigate electromagnetic interference.
  5. Confirm successful module detection via the Ovation HMI diagnostic interface and verify channel signal stability post-installation.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more