PRODUCT SKU : 1C31125G02

PRODUCT TYPE : Digital Output Modules

PRODUCT VENDOR : EMERSON


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for discrete output signal execution in Ovation control platforms, the Emerson 1C31125G02 (1C31125G02 Digital Output Personality Module) provides direct physical execution of 16-channel switched output control.

Hardware Specifications

Parameter Specification
Model 1C31125G02
Brand Emerson
Origin Manufacturer-defined
Weight 0.16 kg
Dimensions Standard Ovation PMOD form factor
Operating Temp Industrial standard range
Power Consumption System-dependent load
Output Count 16 Channels
Output Rating 3.15 A at 250 VAC

Channel-to-channel Isolation

The 1C31125G02 module provides 16 discrete output channels capable of switching loads up to 3.15 A at 250 VAC. The module architecture features channel-to-channel isolation to prevent potential faults in one output circuit from propagating to adjacent channels or the internal backplane bus. This electrical isolation ensures that switching transients generated by inductive loads are contained within the output path, maintaining the signal integrity required for precise discrete control. The module operates as a personality interface within the I/O rack, processing high-level logic commands into physical contact state changes for field-connected actuators or relay arrays.

Frequently Asked Questions

Q: Does the 1C31125G02 support hot-swap replacement in the Ovation I/O chassis?

A: The module is designed for hot-swap operations. Operators must ensure that the associated control loops are inhibited in the engineering workstation software prior to module extraction to prevent unexpected state transitions of field devices.

Q: What are the restrictions regarding inductive load switching with this module?

A: The module is rated for 3.15 A at 250 VAC. When switching high-inductance loads, verify that appropriate suppression (e.g., MOV or RC snubbers) is utilized on the field side to mitigate high-voltage flyback and extend the service life of the internal output switching components.

Field Installation Guidelines

  1. Inspect the I/O rack slot for connector cleanliness and backplane alignment before installing the 1C31125G02.
  2. Seat the module firmly to ensure secure engagement with the backplane bus, allowing proper power and data communication.
  3. Terminate field output wiring to the designated terminal block assembly, ensuring that conductor gauge meets the current-carrying requirements of the load.
  4. Route output cabling in designated low-voltage trays, maintaining physical separation from sensitive analog input signal paths to avoid electromagnetic coupling.
  5. Confirm output status by monitoring the module front-panel LEDs and performing a logic-level functional test via the Ovation controller HMI.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Demystifying the DDE Protocol in Legacy Industrial Automation Systems

Demystifying the DDE Protocol in Legacy Industrial Automation Systems

Modern control systems rely heavily on seamless interprocess communication to exchange operational data between software programs. Microsoft first introduced the Dynamic Data Exchange (DDE) protocol in 1987 to enable real-time data sharing. In factory automation, DDE served as an early bridge between control software and Windows desktop applications. Therefore, understanding DDE mechanics provides crucial insights into how legacy industrial networks established software-level connectivity.

Read more
Demystifying CPU Communication Ports in Siemens PLC Architectures

Demystifying CPU Communication Ports in Siemens PLC Architectures

Industrial automation relies heavily on robust data exchange between devices. Without seamless connectivity, field instruments, network switches, human-machine interfaces, and programmable logic controllers cannot coordinate effectively. Therefore, understanding the various CPU communication ports available in Siemens hardware ensures efficient factory automation design and seamless system integration.

Read more
Mastering the Siemens PLC Scan Cycle: How the CPU Executes Automation Programs

Mastering the Siemens PLC Scan Cycle: How the CPU Executes Automation Programs

Industrial automation relies heavily on programmable logic controllers (PLCs) to manage complex manufacturing processes. Many engineers dive straight into programming without mastering the underlying architecture. However, understanding how a PLC CPU executes a program ensures reliable system design. Therefore, mastering the scan cycle optimizes both performance and troubleshooting in modern control systems.

Read more