Skip to content

What are you looking for?


You may also like

CPU Module | Yokogawa NFCP10O-S0O S3 for FCN-100 ControllersCPU Module | Yokogawa NFCP10O-S0O S3 for FCN-100 ControllersCPU Module | Yokogawa NFCP10O-S0O S3 for FCN-100 Controllers
CPU Module | Yokogawa NFCP10O-S0O S3 for FCN-100 Controllers
CPU Module | Yokogawa NFCP10O-S0O S3 for FCN-100 Controllers
CPU Module | Yokogawa NFCP10O-S0O S3 for FCN-100 Controllers

CPU Module | Yokogawa NFCP10O-S0O S3 for FCN-100 Controllers


Only 10 left - Selling fast

PRODUCT SKU : NFCP100-S00

PRODUCT TYPE : CPU Module

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The NFCP10O-S0O is a high-efficiency CPU module from Yokogawa, part of the S3 series. Designed for FCN-100 autonomous controllers, this module delivers reliable processing with low power consumption in a compact form factor. Its versatile communication interfaces and flexible mounting options make it suitable for a wide range of industrial automation applications.

Key Features

  • Low Power Consumption: Operates under 5 W at 24 VDC

  • Flexible Connectivity: Supports RS-485 and Ethernet communication interfaces

  • Wide Operating Conditions: Functionality maintained from 0°C to 55°C, with storage up to 70°C

  • Compact Design: Small footprint allows DIN rail or panel mounting

  • High Reliability: 5% to 95% RH non-condensing humidity tolerance

Technical Specifications

  • Model Number: NFCP10O-S0O

  • Series: S3 CPU Module

  • Operating Voltage: 24 VDC

  • Power Consumption: <5 W

  • Communication Interfaces: RS-485, Ethernet

  • Operating Temperature: 0°C to +55°C

  • Storage Temperature: -25°C to +70°C

  • Humidity Range: 5% to 95% RH (non-condensing)

  • Mounting Options: DIN rail or panel

  • System Compatibility: FCN-100 autonomous controllers

Applications

  • Standalone or distributed process control systems

  • Small- to medium-scale automation projects

  • Real-time monitoring and control in FCN-100 systems

  • Compact industrial installations where space is limited

FAQ

Q: Can NFCP10O-S0O operate in high-humidity environments?
A: Yes, it supports 5% to 95% RH non-condensing conditions.

Q: What mounting options are available?
A: The module can be installed on DIN rails or mounted on panels.

Q: Is it compatible with FCN-100 controllers?
A: Yes, it is specifically designed for FCN-100 autonomous controllers.

Similar Model Comparison

  • NFCP10O-S1: Enhanced memory and higher communication speed for larger applications

  • NFCP20O-S0O: Dual-core processor for more demanding tasks

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more