Product Description

The GE Fanuc VersaMax IC200UDD020 is a compact micro PLC controller designed for small to mid-range automation tasks. It integrates 12 DC inputs and 8 DC source outputs, providing a total of 20 I/O points. With built-in high-speed counters and flexible logic input options, this controller delivers reliable performance for industrial control applications.

Technical Specifications

  • Manufacturer: GE Fanuc Emerson

  • Model / Part Number: IC200UDD020

  • Product Line: VersaMax

  • Product Type: Micro PLC Controller

  • Weight: 2.00 lbs (0.91 kg)

  • Rated Supply Voltage: 24 VDC

  • DC Power Range: 19.2–30 VDC

  • Hold-Up Time: 10 ms at 19.2 VDC

  • Maximum Inrush Current: 1 A at 30 VDC

  • Inrush Duration: 10 ms for 1 A

  • Typical Input Current: 0.2 A at 24 VDC

  • Input Power Rating: 5 W

  • Inputs: 12 DC logic inputs (positive or negative logic)

  • Outputs: 8 DC source outputs

  • High-Speed Counters:

    • 4 × Type A

    • 1 × Type A and 1 × Type B

    • 4 × Type A_32

    • 1 × Type A_32 and 1 × Type B_32

Application Scenarios

The IC200UDD020 is suitable for compact automation systems such as packaging machines, conveyor control, and distributed I/O applications. Its high-speed counter support makes it ideal for applications requiring precise pulse counting and motion control.

FAQ

Q: How many I/O points are available on the IC200UDD020?  A: It provides 20 total points, with 12 inputs and 8 outputs.

Q: What type of outputs does this controller support?  A: It uses DC source outputs, suitable for driving DC loads.

Q: Does the controller support high-speed counting?  A: Yes, it includes multiple high-speed counter configurations for advanced control tasks.

Comparison with Similar Models

  • IC200UDD040: Higher I/O density, suitable for larger systems.

  • IC200UDD010: Lower I/O count, optimized for smaller applications. The IC200UDD020 offers a balanced mid-range solution with integrated high-speed counters.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more