PRODUCT SKU : CON021+PR6424/002-030

PRODUCT TYPE : Proximity Sensors

PRODUCT VENDOR : EMERSON


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for high-frequency displacement monitoring in rotating machinery, the Emerson Epro CON021+PR6424/002-030 (CON021+PR6424) Eddy Current Sensor system provides direct physical execution of dynamic signal acquisition and conditioning for axial and radial shaft movement.

Hardware Specifications

Parameter Specification
Model CON021+PR6424/002-030
Brand Emerson Epro
Origin Germany
Weight 0.12 kg (Converter)
Dimensions Standard DIN-rail mount (Converter)
Operating Temp -30 deg C to 100 deg C
Power Consumption 23 VDC to 32 VDC (Supply)
Frequency Range 0 Hz to 20,000 Hz

Mechanical Monitoring and TSI Integration

The system relies on eddy-current probe scaling to convert target distance into a proportional voltage signal. Achieving valid diagnostic data requires strict gap voltage validation; the transducer must be positioned to operate within the defined nominal air gap of 2.7 mm to ensure measurement linearity. The CON021 converter processes the transducer output to achieve a sensitivity of 4 V/mm. To maintain signal fidelity in high-noise environments, the system utilizes cross-talk suppression through high-quality shielding of the Lemo-plug transducer interface. This prevents electromagnetic interference from corrupting the dynamic waveform, which is necessary for analyzing rotor dynamics such as orbital motion and shaft eccentricity.

Frequently Asked Questions

Q: Can the CON021 converter be used with different cable lengths than provided?

A: No. The CON021 and PR6424 are a calibrated signal chain. Altering the transducer cable length modifies the circuit's resonant frequency and impedance, leading to significant errors in sensitivity and linearity.

Q: What is the impact of supply voltage fluctuations on the output signal?

A: The CON021 is designed to operate within a -23 VDC to -32 VDC range. Fluctuations outside this range may impact the signal conditioning stability, potentially resulting in drift or non-linear output response during high-frequency signal peaks.

Field Installation Guidelines

  1. Probe Gap Setting: Use a feeler gauge to set the sensor at the nominal 2.7 mm air gap. Ensure the measurement target is aligned with the center of the probe tip to maintain the sensitivity rating.
  2. Mounting: Secure the CON021 converter using the M5 screws provided. Ensure the housing is grounded to the instrument rack to mitigate electrical noise.
  3. Signal Cabling: Terminate the transducer at the CON021 using the self-locking Lemo-plug. For the supply and output terminals, use wire not exceeding 1.5 mm in cross-section to ensure secure fitment in the screw terminals.
  4. Environment: Although the housing provides IP20 protection, ensure the converter is installed within an enclosure that prevents exposure to moisture or conductive dust, which can create signal leakage paths.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more