Skip to content

What are you looking for?


You may also like

Allen-Bradley ControlLogix 1756-OX8I | Isolated Contact ModuleAllen-Bradley ControlLogix 1756-OX8I | Isolated Contact ModuleAllen-Bradley ControlLogix 1756-OX8I | Isolated Contact Module
Allen-Bradley ControlLogix 1756-OX8I | Isolated Contact Module
Allen-Bradley ControlLogix 1756-OX8I | Isolated Contact Module
Allen-Bradley ControlLogix 1756-OX8I | Isolated Contact Module

Allen-Bradley ControlLogix 1756-OX8I | Isolated Contact Module


Only 10 left - Selling fast

PRODUCT SKU : 1756-OX8I

PRODUCT TYPE : Isolated Contact Output Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The Allen-Bradley 1756-OX8I is an isolated contact output module for ControlLogix systems, designed to provide reliable discrete signal control with electrical isolation. It ensures precise operation while protecting the controller from high-voltage spikes or noise from connected field devices.

Technical Specifications

Electrical & Output

  • Model: 1756-OX8I

  • Module Type: Isolated Contact Output

  • Output Points: 8 isolated contacts

  • Output Voltage: Up to 30V DC / 120V AC

  • Output Current: 2A per channel, 16A total

  • Isolation: Channel-to-channel and channel-to-backplane isolation

  • Response Time: 2 ms typical

Compatibility & Mounting

  • Compatible Controller Series: Allen-Bradley ControlLogix 1756

  • Mounting: Standard ControlLogix backplane

  • Module Width: 1 slot

Environmental Ratings

  • Operating Temperature: 0°C to 60°C

  • Storage Temperature: -40°C to 85°C

  • Relative Humidity: 5%–95%, non-condensing

  • Vibration Tolerance: 5G, 10–500 Hz

Physical Dimensions

  • Length: 12.5 cm

  • Width: 3.5 cm

  • Height: 13.0 cm

  • Weight: 0.3 kg

Applications

The 1756-OX8I is ideal for isolated discrete signal control in industrial environments, protecting the ControlLogix processor from electrical noise or high-voltage interference. Typical use includes motor control, relay-driven devices, and field actuator switching.

FAQ

Q: How many channels does the 1756-OX8I support?
A: The module provides 8 isolated contact outputs.

Q: Is this module compatible with all ControlLogix controllers?
A: It is compatible with Allen-Bradley ControlLogix 1756 series processors.

Q: What kind of voltage can it handle?
A: Supports up to 30V DC and 120V AC per channel.

Q: Does it provide electrical isolation?
A: Yes, both channel-to-channel and channel-to-backplane isolation are provided.

 

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more