Product Description

The Allen-Bradley 1756-IB16ISOE is a ControlLogix digital input module designed for sequence-of-events (SOE) applications. It provides 16 individually isolated DC inputs, enabling precise event capture with high-speed response. The module supports both sink and source configurations, making it versatile for industrial monitoring and control systems.

Technical Specifications

Product Description

The Allen-Bradley 1794-IP4 is a Flex I/O pulse counter module with four input channels, designed for distributed control applications. It provides high-speed counting capability with a maximum input frequency of 100 kHz, making it suitable for precise monitoring of pulse signals in industrial automation systems.

Technical Specifications

  • Manufacturer: Allen-Bradley

  • Product Line: Flex I/O 1794

  • Part Number: 1794-IP4

  • Weight: 0.25 lbs (0.11 kg)

  • Inputs: 4 channels, grouped into 2 input groups

  • Minimum Pulse Width: 2 µs

  • Input Frequency: Up to 100 kHz

  • Terminal Base Compatibility: 1794-TB2, -TB3, -TB3S, -TBN, -TBKD

  • ON-State Voltage Range: 6–26.4 V DC (nominal 24 V DC)

  • OFF-State Voltage Range: -26.4 to 3 V DC max

  • Input Current: 3 mA @ 6 V DC

  • Flexbus Current: 5 mA @ 5 V DC

  • Isolation Voltage: 500 V DC

  • Power Dissipation: 5 W max @ 26.4 V DC

  • Thermal Dissipation: 17.1 BTU/hr max @ 26.4 V DC

  • Enclosure Type: Open-style, DIN rail mounting

  • Operating Temperature: 0–55 °C (32–131 °F)

  • Storage Temperature: -40–85 °C (-40–185 °F)

  • Vibration Resistance: 5 g @ 10–500 Hz

  • Shock Resistance: 30 g

Features

  • Four-channel pulse counter for distributed I/O systems

  • High-speed input capability up to 100 kHz

  • Compact Flex I/O design for modular installation

  • DIN rail mounting for easy integration

  • Isolated inputs for improved signal reliability

Application Scenarios

  • Machine Monitoring: High-speed pulse counting for rotary encoders and sensors

  • Process Automation: Accurate input measurement for distributed control systems

  • Legacy Flex I/O Installations: Expansion module for existing Flex I/O networks

FAQ

  • Q: How many input channels does the 1794-IP4 provide?  A: Four input channels, grouped into two sets.

  • Q: What is the maximum input frequency?  A: 100 kHz.

  • Q: Which terminal bases are supported?  A: 1794-TB2, -TB3, -TB3S, -TBN, and -TBKD.

  • Q: What isolation voltage is provided?  A: 500 V DC.

  • Q: How does this compare to the 1794-IP2?  A: The 1794-IP4 supports four channels, while the 1794-IP2 provides two, making the IP4 suitable for higher-density applications.

Manufacturer: Allen-Bradley

  • Product Line: ControlLogix

  • Part Number: 1756-IB16ISOE

  • Category: PLCs

  • Weight: 0.44 lbs (0.20 kg)

  • Module Type: Digital DC Isolated Input (SOE)

  • Inputs: 16 isolated channels

  • Input Voltage Range: 24–48 V DC (sink/source)

  • Operating Voltage Range: 10–55 V DC

  • Input Delay Time: 50 µs + selectable filter time

  • Minimum Operating Current: 5.5 mA at 55 V DC

  • Maximum Operating Current: 2 mA at 10 V DC

  • Off-State Current (Max): 1.5 mA

  • Power Dissipation: 5.5 W at 60 °C

  • Backplane Current Draw:

    • 275 mA @ 5 V DC

    • 2 mA @ 24 V DC

  • Terminal Blocks: 1756-TBCH, 1756-TBS6H (removable)

  • Isolation Voltage: 75 V continuous; type-tested at 1200 V AC for 2 s

Features

  • High-speed event capture with 50 µs response

  • Individually isolated inputs for improved reliability

  • Supports both sink and source wiring configurations

  • Designed for sequence-of-events monitoring in critical applications

  • Compatible with removable terminal blocks for simplified wiring

Application Scenarios

  • Power System Monitoring: Event capture for fault detection and logging

  • Industrial Automation: Precise input tracking for safety and control systems

  • Critical Infrastructure: Sequence-of-events recording in energy and utility networks

FAQ

  • Q: How many inputs does the 1756-IB16ISOE provide?  A: Sixteen individually isolated DC inputs.

  • Q: What is the input delay time?  A: 50 microseconds plus selectable filter time.

  • Q: Which terminal blocks are compatible?  A: 1756-TBCH and 1756-TBS6H.

  • Q: What isolation voltage is supported?  A: 75 V continuous, tested at 1200 V AC for 2 seconds.

  • Q: How does this compare to the 1756-IB16?  A: The 1756-IB16ISOE provides isolated inputs and SOE functionality, while the 1756-IB16 is a standard DC input module without event sequencing.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Successful control system deployment begins with thoroughly reviewing manufacturer technical documentation. Controllers from major brands like Allen-Bradley, Siemens, and Schneider Electric feature unique terminal layouts. Engineers must verify voltage requirements before connecting power cables to prevent catastrophic equipment damage. Standard line connections require strict adherence to regional electrical codes and proper wire color coding. Furthermore, panel builders should always establish a robust low-impedance ground connection using at least 16-AWG copper conductor tied directly to the main plant grounding grid.

Read more
Demystifying Programmable Logic Controllers: Comprehensive Guide to PLC Classification and Selection in Industrial Automation

Demystifying Programmable Logic Controllers: Comprehensive Guide to PLC Classification and Selection in Industrial Automation

Modern industrial automation heavily relies on Programmable Logic Controllers (PLCs) to drive factory floor efficiency. Over my 15 years as an industrial automation expert working with DCS, TSI, and control systems, I have seen PLCs evolve into the central nervous system of modern manufacturing. Selecting the right controller requires a deep understanding of PLC types based on physical size, hardware architecture, and power supply configurations.

Read more
Comprehensive Guide to PLC Types in Modern Industrial Automation

Comprehensive Guide to PLC Types in Modern Industrial Automation

Modern industrial automation relies on programmable logic controllers to govern critical factory operations. System integrators classify PLCs based on scale, hardware architecture, and power supply design. Understanding these core categories enables automation engineers to select the right control system architecture. Consequently, proper hardware selection optimizes performance while minimizing long-term operational costs.

Read more