Overview

The 1771-P4S is an Allen-Bradley PLC 5 power supply module designed to provide stable 5VDC power for 1771 series I/O systems. Compact and reliable, this module is intended for use in single-slot 1771 chassis applications and ensures consistent performance across a range of industrial environments.

Technical Specifications

  • Model: 1771-P4S

  • Manufacturer: Allen-Bradley

  • Product Type: PLC 5 Power Supply Module

  • Input Voltage Range: 97–132 VAC

  • Nominal Input Voltage: 120 VAC

  • Input Frequency: 47–63 Hz

  • Maximum Output Current: 8 A

  • Output Voltage: 5 VDC

  • Module Width: 1 slot

  • Backplane Output Current: 8 A at 5 VDC

  • Fuse: 1.5 A, 250 V, slow-blow

  • Terminal Block: 5-position; compatible with A/B P/N 941274-05 and Wago P/N 231-205/000-008

  • Maximum Real Input Power: 59 W

  • Maximum Apparent Input Power: 89 VA

  • Maximum Former Load: 148 VA

  • Wire Size: 14 AWG max for single wire connections

  • Paralleled Modules: Supports -LSP, -LWP, -XP, -ZP, -P4S

  • Installation Location: 1771 chassis, 1 slot

  • Weight: 1.94 lbs (0.88 kg)

Features

  • Provides regulated 5 VDC output for 1771 series I/O modules

  • Single-slot design allows compact integration into PLC 5 chassis

  • Built-in slow-blow fuse ensures overload protection

  • Compatible with standard 1771 cabling and terminal blocks

  • Reliable operation for industrial control and automation systems

Applications

Ideal for powering PLC 5 I/O modules in manufacturing, process control, and automation environments requiring 5 VDC power with up to 8 A output.

FAQ

Q: Can this module be paralleled with other power supplies?
A: Yes, the 1771-P4S supports parallel operation with -LSP, -LWP, -XP, -ZP, and other -P4S modules.

Q: What chassis is compatible?
A: Designed for use in a 1771 series chassis with a single slot.

Q: What type of protection is included?
A: Includes a 1.5 A, 250 V slow-blow fuse for overload protection.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more