Skip to content

What are you looking for?


You may also like

ABB Bailey INIIT03 Infi-Net to Infi-Net Local Transfer Interface ModuleABB Bailey INIIT03 Infi-Net to Infi-Net Local Transfer Interface ModuleABB Bailey INIIT03 Infi-Net to Infi-Net Local Transfer Interface Module
ABB Bailey INIIT03 Infi-Net to Infi-Net Local Transfer Interface Module
ABB Bailey INIIT03 Infi-Net to Infi-Net Local Transfer Interface Module
ABB Bailey INIIT03 Infi-Net to Infi-Net Local Transfer Interface Module

ABB Bailey INIIT03 Infi-Net to Infi-Net Local Transfer Interface Module


Only 10 left - Selling fast

PRODUCT SKU : INIIT03

PRODUCT TYPE : Network Interface Module

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Description

The ABB INIIT03 is a high-speed network communication module engineered for the Bailey INFI 90 and Symphony Plus distributed control systems. This local transfer interface acts as a vital bridge between two separate Infi-Net communication rings, allowing for the seamless exchange of data packets and process variables across different network segments. By facilitating local network expansion, the INIIT03 enables larger plant architectures to maintain high-speed, deterministic performance while keeping control traffic organized. It is essential for complex industrial facilities that require synchronized communication between multiple localized control loops without compromising the integrity of the primary plant loop.

Specifications

  • Brand: ABB Bailey

  • Model Number: INIIT03

  • Product Series: INFI 90 / Symphony Plus

  • Functional Category: Local Network Transfer Interface

  • Compatibility: INFI-Net (Cnet) Architecture

  • Data Transmission Rate: High-speed synchronous transfer

  • Bus Interface: Harmony Control Bus / Slave Expander Bus

  • Mounting: Occupies one slot in a standard Module Mounting Unit (MMU)

  • Power Supply: +5 VDC via system backplane

  • Operating Temperature: 0 to 70 degrees Celsius

  • Fault Tolerance: Supports redundant network loop configurations

Features

  • Inter-Ring Communication: Provides a dedicated hardware gateway to link adjacent Infi-Net segments for unified system monitoring and control.

  • Deterministic Data Management: Employs advanced protocol handling to ensure time-critical process data is transferred with minimal latency.

  • Network Isolation and Security: Prevents localized network faults in one ring from propagating to the other, enhancing overall system availability.

  • High-Volume Buffering: Integrated memory architecture manages incoming and outgoing data packets to prevent network congestion during peak cycles.

  • On-Board Diagnostics: Features real-time hardware monitoring with front-panel LED indicators to provide immediate feedback on network status and error conditions.

  • Plug-and-Play Compatibility: Designed for standard INFI 90 hardware racks, allowing for straightforward integration into existing control cabinets.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more
Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Proper wire labeling forms the cornerstone of reliable control system installation and long-term maintenance. In complex industrial automation environments, technicians terminate thousands of conductor ends inside control panels, marshalling racks, and field junction boxes. Ferrules serve as individual tube-shaped sleeve markers slipped onto conductors before final termination. While technicians historically relied on pre-printed individual letter rings, modern control panel builders utilize automated ferrule printing machines. These thermal-transfer printers generate durable, single-sleeve heat-shrink tags directly matching approved wiring schematics, significantly accelerating cabinet assembly workflows.

Read more