Skip to content

What are you looking for?


You may also like

9905-068 | Woodward | 2301A Load Sharing and Speed Control9905-068 | Woodward | 2301A Load Sharing and Speed Control9905-068 | Woodward | 2301A Load Sharing and Speed Control
9905-068 | Woodward | 2301A Load Sharing and Speed Control
9905-068 | Woodward | 2301A Load Sharing and Speed Control
9905-068 | Woodward | 2301A Load Sharing and Speed Control

9905-068 | Woodward | 2301A Load Sharing and Speed Control


Only 10 left - Selling fast

PRODUCT SKU : 9905-068

PRODUCT TYPE : Speed Control Modules

PRODUCT VENDOR : Woodward


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for prime mover load distribution and rotational velocity regulation, the Woodward 9905-068 (9905-068 Load Sharing and Speed Control) provides direct physical/electrical execution of speed sensing and actuator output control within governor systems.

Hardware Specifications

Parameter Specification
Model 9905-068
Brand Woodward
Origin Not specified
Weight < 4 lbs
Dimensions 15.25 x 7.125 x 2.5 in
Operating Temp -40 to 85 deg C
Power Consumption <= 15 W
Input Voltage 20-40 VDC
Speed Sensor Input Impedance 100-300 Ohm

Actuator Loop Feedback Response

The 9905-068 2301A control module modulates the fuel system via a PID-based output stage designed to maintain engine speed setpoints. To ensure a stable actuator loop feedback response, the controller utilizes internal compensation, gain, and reset potentiometers, which allow for site-specific tuning to match the engine's mechanical time constants. If the prime mover fails to achieve rated no-load speed or exhibits hunting behavior during load sharing, these potentiometers must be adjusted to align the controller output with the actuator's physical response. The unit continuously monitors the load signal to facilitate precise synchronization and load sharing in multi-generator applications, requiring correct current transformer phasing for stable operation.

Frequently Asked Questions

Q: What is the procedure for verifying correct phase operation of the load signal?

A: With the prime mover in isochronous mode and not running, load the generator to near-full capacity and measure the voltage between the negative terminal 11 and positive terminal 13. If measurements indicate a phase error, rotate and record voltage/polarity across the three current transformers to verify correction.

Q: How can I optimize the control loop if the engine does not equalize for rated speed?

A: If speed equalization errors occur, verify the control operation and refine the actuator compensation, gain, and reset potentiometer settings. Ensure these adjustments are performed incrementally while observing the governor's response to step-load changes.

Field Installation Guidelines

  1. Mounting: Secure the control module in an industrial enclosure using the specified mounting dimensions. Ensure the unit is protected from high-humidity and high-vibration environments, maintaining operation within the -40 to 85 deg C range.
  2. Wiring: Use shielded cabling for speed sensor inputs and load signal connections to prevent electromagnetic interference. Terminate shields at the cabinet ground point to minimize ground loops that could introduce signal instability.
  3. Power Connection: Connect a regulated 20-40 VDC power supply to the unit. Ensure the power source is capable of delivering consistent current, as fluctuations can degrade the precision of the speed sensing and control output.
  4. Validation: Prior to initial startup, perform a cold-loop test to verify current transformer phasing and load signal polarities. Ensure the speed sensor impedance (100-300 Ohm) matches the MPU or proximity probe specifications before commissioning the prime mover into parallel operation.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
The Shift to Flexible IO Modules in Modern Industrial Automation

The Shift to Flexible IO Modules in Modern Industrial Automation

Traditional control systems rely on dedicated Input Output (IO) cards for industrial automation. Each conventional module processes a single signal type, such as Digital Input (DI), Digital Output (DO), Analog Input (AI), or Analog Output (AO). A standard 16-channel card accepts only one specific channel type across all ports. This inflexible hardware design often creates severe engineering bottlenecks during project execution. Engineers frequently must install entirely new cards to accommodate a single extra sensor. Consequently, late design changes increase control cabinet space requirements and drive up project costs.

Read more
DCS Commissioning Steps in Industrial Automation Projects

DCS Commissioning Steps in Industrial Automation Projects

Commissioning a Distributed Control System (DCS) represents a crucial milestone when deploying modern process automation infrastructure. Field engineers must execute systematic verification steps to transition complex control hardware from static installation to dynamic plant control. Proper commissioning ensures that controllers, I/O modules, network switches, and HMI software operate in strict compliance with engineering design specifications before introducing live process fluids.

Read more
PLC and DCS Control System Spares Strategy: Engineering Guidelines

PLC and DCS Control System Spares Strategy: Engineering Guidelines

Modern factory automation relies on high-speed fiber optic backbones to link distributed control systems across noise-intensive industrial environments. Unlike copper wiring, optical fibers transmit data via light pulses, making them completely immune to electromagnetic interference (EMI). Field engineers must master optical cable joining and fusion splicing techniques to guarantee low-loss data transmission across critical Programmable Logic Controller (PLC) and Distributed Control System (DCS) nodes.