PRODUCT SKU : 9905-968

PRODUCT TYPE : Analog Input Modules

PRODUCT VENDOR : Woodward


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for multi-channel sensor signal acquisition in gas turbine control platforms, the Woodward 9905-968 (9905-968 Channel Analog Input Module) provides direct physical/electrical execution. The hardware conditions and converts 4-20 mA analog inputs from field sensors into digital data streams for processing by central governing logic. Housed in a 16 cm x 16 cm x 12 cm enclosure weighing 1.82 kg, the unit routes conditioned real-time telemetry across dedicated Linknet communication channels.

Hardware Specifications

Parameter Specification
Model 9905-968
Brand Woodward
Origin United States
Weight 1.82 kg
Dimensions 16 cm x 16 cm x 12 cm
Operating Temp Standard Industrial Range (-20 deg C to +60 deg C)
Power Consumption Linknet Network / External 24 VDC Powered
Input Channel Count 6 Channels
Signal Input Type 4-20 mA Current Loop
Signal Processing Analog-to-Digital Conversion with Signal Conditioning
Architecture Linknet I/O Network Component

Actuator Loop Feedback Response

The Woodward 9905-968 Linknet Analog Input Module incorporates low-latency signal filtering and digitizing logic designed to preserve actuator loop feedback response. By executing high-speed sampling across all six 4-20 mA channels, the internal circuitry scales field pressure, temperature, and position sensor inputs without phase delay. Continuous signal conditioning suppresses high-frequency electrical noise, supplying noise-free telemetry to the main controller to prevent phase lag or hunting in hydraulic actuator control loops.

Frequently Asked Questions

Q: How is signal wire shield grounding handled for the 4-20 mA input loops?

A: All 4-20 mA input loop signal cables must use individual shielded twisted pairs. Connect signal cable drain shields to the enclosure single-point grounding bus bar at one end only to prevent ground loops from introducing current measurement offsets.

Q: Can channels be hot-swapped while the Linknet network is actively processing signals?

A: Live removal or insertion of the module while powered must follow strict safety procedures. De-energize field loops or disconnect the Linknet communication header to avoid transient bus disruptions and improper diagnostic trips within the primary control software.

Field Installation Guidelines

Mount the module inside a grounded metal control cabinet using the standard mounting hardware to ensure structural stability against mechanical vibration. Wire the 4-20 mA input channels using shielded twisted-pair conductors, maintaining physical separation between low-level analog signal lines and high-voltage AC lines or inductive output wiring. Ensure the cabinet earth ground strap is bonded directly to the main grounding point with a short, low-impedance conductor prior to powering the unit.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Will PLCs Become Obsolete? The Future of Control Systems in Industry 4.0

Will PLCs Become Obsolete? The Future of Control Systems in Industry 4.0

Modern manufacturing is undergoing a rapid technological transformation driven by Industry 4.0 innovations. Technologies like Artificial Intelligence (AI), Machine Learning (ML), and the Industrial Internet of Things (IIoT) are dominating discussions across the factory automation sector. Consequently, many engineers wonder if these advanced digital tools will eventually replace traditional Programmable Logic Controllers (PLCs). However, evaluating the core physics of industrial operations reveals a very different reality for control systems.

Read more
Demystifying Open Platform Communication (OPC): The Backbone of Industrial Interoperability

Demystifying Open Platform Communication (OPC): The Backbone of Industrial Interoperability

Interoperability remains a cornerstone requirement for modern smart factories and process automation. Open Platform Communication (OPC) bridges the gap between disparate hardware platforms, control systems, and visualization software. By establishing a universal communication standard, OPC allows field controllers, SCADA platforms, and enterprise software from different vendors to exchange real-time data seamlessly.

Read more
Understanding Siemens PLC Memory Cards: MMC, SMC, and SD Solutions in Industrial Automation

Understanding Siemens PLC Memory Cards: MMC, SMC, and SD Solutions in Industrial Automation

Memory management plays a pivotal role in maintaining control system reliability across modern manufacturing plants. Industrial control systems rely on specialized memory cards to store project logic, firmware updates, and retentive system data. Siemens uses several memory architectures, including Micro Memory Cards (MMC) and SIMATIC Memory Cards (SMC). Engineers must understand these hardware variations to ensure zero data loss and minimize downtime during maintenance routines.

Read more