PRODUCT SKU : 8237-1600

PRODUCT TYPE : Overspeed Protection Systems

PRODUCT VENDOR : Woodward


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for overspeed detection in turbine control systems, the Woodward 8237-1600 (8237-1600 Overspeed Detection Device) provides direct electrical execution of triple modular redundant (TMR) speed sensing and safety trip logic.

Hardware Specifications

Parameter Specification
Model 8237-1600
Brand Woodward
Weight < 23 lbs
Dimensions 13.0 in x 17.5 in x 6.25 in
Operating Temp -20 deg C to +60 deg C
Power Consumption Not specified
Inrush Current 10 A at 115 VAC / 20 A at 220 VAC
Ingress Protection IP56

Actuator Loop Feedback Response and Thermal Heat Sink Dissipation Profiles

The 8237-1600 utilizes a 2oo3 (two-out-of-three) voted architecture to process MPU and acceleration inputs, ensuring fail-safe execution of turbine shutdown commands. The system manages actuator loop feedback response by integrating MPU-based speed sensing with dedicated 4-20 mA speed readout outputs. To sustain operational integrity in Class 3C2 chemical environments, the electronics utilize conformal coatings resistant to sulfur contamination. Internal thermal heat sink dissipation profiles are optimized for standard cabinet mounting, allowing for online module replacement without compromising the protection logic provided by the remaining two active modules. The interface supports Modbus communication for external status polling while maintaining independent relay-driven trip paths for immediate prime mover isolation.

Frequently Asked Questions

Q: Can the 8237-1600 modules be replaced while the turbine is in operation?

A: Yes. The triple module design supports online maintenance. A single module can be extracted for repair or replacement while the other two modules continue to monitor speed and execute trip logic.

Q: What is the purpose of the internal generator feature in this device?

A: The internal generator allows the system to perform routine speed tests without requiring actual turbine rotation, enabling verification of trip point logic and relay response times during scheduled maintenance periods.

Field Installation Guidelines

  • Mounting: Ensure the panel-mount structure is secured to a rigid surface. Verify that the clearance around the 13.0 in x 17.5 in x 6.25 in housing allows for proper airflow and front-plate access.
  • Environmental Protection: To maintain the IP56 rating, ensure all cable penetrations and mounting gaskets are correctly seated. Do not expose the unit to environments exceeding the specified 95% humidity limit.
  • Wiring: Connect MPU sensors to the independent module inputs. Use shielded twisted-pair cables, terminating the shield at the cabinet ground bus to minimize noise interference in the 4-20 mA analog output loops.
  • Powering: The unit accepts high or low voltage inputs. If utilizing redundant power sources, ensure both inputs are routed through isolated circuit protection to prevent a single power fault from affecting all modules.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
The Shift to Flexible IO Modules in Modern Industrial Automation

The Shift to Flexible IO Modules in Modern Industrial Automation

Traditional control systems rely on dedicated Input Output (IO) cards for industrial automation. Each conventional module processes a single signal type, such as Digital Input (DI), Digital Output (DO), Analog Input (AI), or Analog Output (AO). A standard 16-channel card accepts only one specific channel type across all ports. This inflexible hardware design often creates severe engineering bottlenecks during project execution. Engineers frequently must install entirely new cards to accommodate a single extra sensor. Consequently, late design changes increase control cabinet space requirements and drive up project costs.

Read more
DCS Commissioning Steps in Industrial Automation Projects

DCS Commissioning Steps in Industrial Automation Projects

Commissioning a Distributed Control System (DCS) represents a crucial milestone when deploying modern process automation infrastructure. Field engineers must execute systematic verification steps to transition complex control hardware from static installation to dynamic plant control. Proper commissioning ensures that controllers, I/O modules, network switches, and HMI software operate in strict compliance with engineering design specifications before introducing live process fluids.

Read more
PLC and DCS Control System Spares Strategy: Engineering Guidelines

PLC and DCS Control System Spares Strategy: Engineering Guidelines

Modern factory automation relies on high-speed fiber optic backbones to link distributed control systems across noise-intensive industrial environments. Unlike copper wiring, optical fibers transmit data via light pulses, making them completely immune to electromagnetic interference (EMI). Field engineers must master optical cable joining and fusion splicing techniques to guarantee low-loss data transmission across critical Programmable Logic Controller (PLC) and Distributed Control System (DCS) nodes.

Read more