PRODUCT SKU : 5X00499G01

PRODUCT TYPE : Digital Input Modules

PRODUCT VENDOR : EMERSON


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for high-density signal acquisition in Ovation control platforms, the Emerson 5X00499G01 (5X00499G01 Digital Input Module) provides direct physical execution of discrete status monitoring across 32 independent channels.

Hardware Specifications

Parameter Specification
Model 5X00499G01
Brand Emerson
Origin USA
Weight Standard Ovation module weight
Dimensions Standard Ovation I/O form factor
Operating Temp Industrial standard range
Power Consumption System-dependent load
Channel Count 32 Digital Inputs
Input Rating 24 VDC

4-20 mA HART Loop Protocol

The 5X00499G01 module incorporates advanced channel-to-channel isolation to prevent ground loop interference when interfacing with various field sensors, including limit switches, pressure sensors, and flow meters. In systems where field instrumentation requires secondary diagnostic verification, the module maintains signal integrity compliant with standard process control loops. The isolation architecture ensures that each of the 32 input channels is electrically independent, minimizing the impact of potential field-side faults on the remaining input channels. Cold junction compensation (CJC) is not required for this discrete module, as it is dedicated to digital state detection rather than thermal analog conversion.

Frequently Asked Questions

Q: Does the 5X00499G01 module support hot-swapping while the Ovation control system is active?

A: The Ovation I/O architecture generally supports online module replacement. Ensure that the associated I/O task is properly inhibited or the channel mapping is verified before removing the module to prevent unintended process state changes or system alarms.

Q: Can the 24 VDC input threshold be adjusted for non-standard signal voltages?

A: No, the input threshold is fixed for standard 24 VDC industrial logic levels. Attempting to use voltage levels outside the specified operating range may result in failure to detect state changes or internal circuitry damage.

Field Installation Guidelines

  1. Ensure the Ovation I/O rack slot is clean and free of debris prior to module insertion; align the module with the backplane guides to prevent pin damage.
  2. Terminate field wiring using the appropriate terminal block assembly; ensure proper torque settings to maintain secure connections for all 32 channels.
  3. Utilize shielded twisted-pair cabling for all input signals to minimize electromagnetic interference (EMI) ingress from nearby power cabling.
  4. Verify that the shield drain wire is connected to a common instrument ground point at the cabinet entry, ensuring consistent reference potential across the I/O system.
  5. Confirm the module status LEDs indicate normal operation upon power-up and verify channel-level status via the Ovation engineering workstation.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Siemens PLC Memory Cards: MMC, SMC, and SD Solutions in Industrial Automation

Understanding Siemens PLC Memory Cards: MMC, SMC, and SD Solutions in Industrial Automation

Memory management plays a pivotal role in maintaining control system reliability across modern manufacturing plants. Industrial control systems rely on specialized memory cards to store project logic, firmware updates, and retentive system data. Siemens uses several memory architectures, including Micro Memory Cards (MMC) and SIMATIC Memory Cards (SMC). Engineers must understand these hardware variations to ensure zero data loss and minimize downtime during maintenance routines.

Read more
Redefining Control Systems: The Rise of Flexible I/O Modules in Industrial Automation

Redefining Control Systems: The Rise of Flexible I/O Modules in Industrial Automation

Conventional input-output architectures often limit engineering agility and inflate long-term inventory costs. Today, Flexible Input/Output Modules (FIOM) are transforming how control system engineers design, commission, and maintain automation infrastructure. By allowing individual channel software configuration, FIOM technology bridges the gap between rigid hardware design and dynamic plant requirements.

Read more
Understanding Modern SCADA Systems: Architecture, Communication Topologies, and Industrial Applications

Understanding Modern SCADA Systems: Architecture, Communication Topologies, and Industrial Applications

Supervisory Control and Data Acquisition (SCADA) systems form the digital backbone of modern industrial automation. They collect critical field data, transmit signals across vast distances, and empower plant operators with real-time process visibility. Across modern infrastructures, SCADA solutions streamline centralized control and maintain continuous operational uptime.

Read more