Skip to content

What are you looking for?


You may also like

5X00167G01 | Emerson | Analog Output Module5X00167G01 | Emerson | Analog Output Module5X00167G01 | Emerson | Analog Output Module
5X00167G01 | Emerson | Analog Output Module
5X00167G01 | Emerson | Analog Output Module
5X00167G01 | Emerson | Analog Output Module

5X00167G01 | Emerson | Analog Output Module


Only 10 left - Selling fast

PRODUCT SKU : 5X00167G01

PRODUCT TYPE : Analog Output Modules

PRODUCT VENDOR : EMERSON


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for high-performance process control in Ovation platforms, the Emerson 5X00167G01 (5X00167G01) provides direct physical execution of 4-channel analog output signaling for field device actuation.

Hardware Specifications

Parameter Specification
Model 5X00167G01
Brand Emerson
Origin Manufacturer-defined
Weight 1.13 kg
Dimensions Standard Ovation module form factor
Operating Temp Industrial standard range
Power Consumption System-dependent load
Channel Count 4 Channels
Output Type Analog Output with HART

4-20 mA HART Loop Protocol

The 5X00167G01 module supports the 4-20 mA HART loop protocol, enabling precise control of final control elements while facilitating bidirectional digital communication for device configuration and diagnostic status reporting. The module is engineered with channel-to-channel isolation to prevent potential interference between independent control loops and to mitigate the risk of ground loops in field-installed instrumentation. This architecture ensures that output commands remain stable despite fluctuations in common-mode voltages. The integrated HART support allows the Ovation controller to poll device variables and maintenance alerts directly through the analog signal path, maintaining full loop visibility without additional hardware.

Frequently Asked Questions

Q: Does the 5X00167G01 support hot-swapping during system operation?

A: The module is designed for hot-swap installation within the Ovation I/O rack. Before physical removal, ensure the corresponding control loops are set to manual mode or inhibited in the Ovation engineering software to prevent uncommanded output fluctuations.

Q: Are there manual configuration jumpers on the module for current range selection?

A: No, the 5X00167G01 is fully software-configurable via the Ovation engineering workstation. All output range scaling and HART enable/disable functions are managed through the system configuration database.

Field Installation Guidelines

  1. Inspect the backplane connector within the I/O chassis for pin alignment and cleanliness prior to module insertion.
  2. Align the module with the chassis guide rails and apply consistent pressure until the backplane interface is fully seated.
  3. Secure the module using the built-in retention mechanism to prevent decoupling under high-vibration conditions.
  4. Terminate field signal wiring to the corresponding terminal block assembly, ensuring shielded twisted-pair cabling is utilized to maintain EMI immunity.
  5. Verify signal continuity and loop integrity via the Ovation diagnostic tools after ensuring the field device power supply is active.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Demystifying the DDE Protocol in Legacy Industrial Automation Systems

Demystifying the DDE Protocol in Legacy Industrial Automation Systems

Modern control systems rely heavily on seamless interprocess communication to exchange operational data between software programs. Microsoft first introduced the Dynamic Data Exchange (DDE) protocol in 1987 to enable real-time data sharing. In factory automation, DDE served as an early bridge between control software and Windows desktop applications. Therefore, understanding DDE mechanics provides crucial insights into how legacy industrial networks established software-level connectivity.

Read more
Demystifying CPU Communication Ports in Siemens PLC Architectures

Demystifying CPU Communication Ports in Siemens PLC Architectures

Industrial automation relies heavily on robust data exchange between devices. Without seamless connectivity, field instruments, network switches, human-machine interfaces, and programmable logic controllers cannot coordinate effectively. Therefore, understanding the various CPU communication ports available in Siemens hardware ensures efficient factory automation design and seamless system integration.

Read more
Mastering the Siemens PLC Scan Cycle: How the CPU Executes Automation Programs

Mastering the Siemens PLC Scan Cycle: How the CPU Executes Automation Programs

Industrial automation relies heavily on programmable logic controllers (PLCs) to manage complex manufacturing processes. Many engineers dive straight into programming without mastering the underlying architecture. However, understanding how a PLC CPU executes a program ensures reliable system design. Therefore, mastering the scan cycle optimizes both performance and troubleshooting in modern control systems.

Read more