Skip to content

What are you looking for?


You may also like

2711P-K10C4D8 Allen Bradley PanelView Plus 6 Operator Interface Terminal2711P-K10C4D8 Allen Bradley PanelView Plus 6 Operator Interface Terminal2711P-K10C4D8 Allen Bradley PanelView Plus 6 Operator Interface Terminal
2711P-K10C4D8 Allen Bradley PanelView Plus 6 Operator Interface Terminal
2711P-K10C4D8 Allen Bradley PanelView Plus 6 Operator Interface Terminal
2711P-K10C4D8 Allen Bradley PanelView Plus 6 Operator Interface Terminal

2711P-K10C4D8 Allen Bradley PanelView Plus 6 Operator Interface Terminal


Only 10 left - Selling fast

PRODUCT SKU : 2711P-K10C4D8

PRODUCT TYPE : Operator Terminal

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The Allen Bradley PanelView Plus 6 2711P-K10C4D8 is a versatile operator terminal designed for industrial automation systems. It combines keypad and touchscreen input, offering flexible control and monitoring with a durable 10.4-inch color display.

Technical Specifications

  • Manufacturer Allen Bradley

  • Product Line PanelView Plus 6

  • Product Type Operator Terminal

  • Part Number 2711P-K10C4D8

  • Weight 8.63 lbs (3.91 kg)

  • Display Size 10.4 inches, TFT color active-matrix

  • Display Area 211 × 158 mm (8.3 × 6.2 in.)

  • Resolution 640 × 480, 18-bit color graphics

  • Backlight CCFL, minimum 50,000 hours at 25 °C, field replaceable

  • Input Type Keypad and touchscreen

  • Keypad Buttons 32 function keys, numeric, navigation, and confirmation keys

  • Operator Input Touchscreen + keypad combination

  • Internal Memory 512 MB Flash, 512 MB RAM

  • Communication Ports Ethernet, RS-232, 2 × USB host

  • Input Voltage Range 18–30 VDC

  • Input Power 18–32 VDC

  • Communication Cable 2711-NC14

  • Series A and B

  • Lifecycle Status End of Life

Application Scenarios

  • Operator interface for machine control and monitoring

  • Supervisory control in production lines

  • Integration with ControlLogix and CompactLogix controllers

FAQ

Q: Can the backlight be replaced in the field?  A: Yes, the CCFL backlight is designed for field replacement and has a long service life.

Q: What communication options are supported?  A: The terminal supports Ethernet, RS-232, and USB host connections.

Q: Does this model support both keypad and touchscreen input?  A: Yes, it provides dual input capability for flexible operator control.

Comparable Models

  • 2711P-T10C4D8: Touchscreen-only version of the same terminal.

  • 2711P-K7C4D8: Smaller 7-inch display with keypad and touchscreen input.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more
Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Proper wire labeling forms the cornerstone of reliable control system installation and long-term maintenance. In complex industrial automation environments, technicians terminate thousands of conductor ends inside control panels, marshalling racks, and field junction boxes. Ferrules serve as individual tube-shaped sleeve markers slipped onto conductors before final termination. While technicians historically relied on pre-printed individual letter rings, modern control panel builders utilize automated ferrule printing machines. These thermal-transfer printers generate durable, single-sleeve heat-shrink tags directly matching approved wiring schematics, significantly accelerating cabinet assembly workflows.

Read more
Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Marshalling cabinets serve as the crucial connection hub between field instruments and centralized processing units. In large DCS and PLC control system architectures, hundreds of multipair field cables run from local junction boxes to the central instrument equipment room. The marshalling cabinet houses field terminal blocks, surge arresters, intrinsic safety isolation barriers, and interposing relays. By segregating field field-wiring terminations from sensitive processor hardware, engineers protect expensive controller backplanes from high-voltage transients. Consequently, this modular separation dramatically streamlines maintenance workflows and simplifies system expansion.

Read more