PRODUCT SKU : 1794-OE4XT

PRODUCT TYPE : Analog Output Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen Bradley 1794-OE4XT serves as a high-performance analog output module within the FLEX™ I/O platform, specifically designed for extreme industrial environments. This "XT" (Extended Temperature) version provides four high-precision analog outputs, converting 12-bit digital values into analog signals to drive actuators, valves, and motor speed controllers. Its ruggedized design ensures stable signal conversion even in unconditioned control cabinets. We supply this module in 100% Brand New and Original condition, meeting the rigorous demands of heavy industry and remote outdoor installations.

Technical Specifications

The 1794-OE4XT provides precise signal modulation through the following technical parameters:

Feature Specification
Manufacturer Allen Bradley (Rockwell Automation)
Module Type Analog Output (FLEX I/O)
Number of Outputs 4 Channels
Resolution 12-Bits
Operating Temperature -20°C to 70°C (-4°F to 158°F)
External Power 24V DC Nominal
Protection Rating IP20
Output Ranges 0-20mA, 4-20mA, +/- 10V (Configuration dependent)
Weight 0.20 lbs (0.09 kg)

Engineering Advantages

The 1794-OE4XT addresses critical environmental and signal integrity challenges in distributed I/O architectures:

  • Extended Thermal Tolerance: The "XT" designation signifies hardware-level resilience against thermal extremes. This module operates reliably between -20°C and 70°C, allowing for deployment in non-climate-controlled environments, such as oil field pumping stations or rooftop HVAC control panels.

  • Granular Control Precision: The 12-bit digital-to-analog converter (DAC) translates digital instructions into subtle physical adjustments. This level of resolution allows for the fine-tuning of proportional valves and variable frequency drives (VFDs), optimizing process efficiency.

  • High-Density DIN Rail Integration: The module utilizes the compact FLEX I/O footprint, minimizing cabinet space requirements. It snaps directly onto a 1794-TB3 or 1794-TBN terminal base, allowing for rapid assembly of high-density I/O racks without complex backplane wiring.

  • Galvanic Isolation: Integrated circuitry isolates the field-side outputs from the logic-side backplane. This protects the central PLC processor from electrical noise and voltage transients common in industrial grounding systems.

FAQs

  • What is the difference between the 1794-OE4 and the 1794-OE4XT?

    The 1794-OE4XT features extended temperature components and specialized manufacturing processes that allow it to operate in a wider temperature range (-20 to 70°C) compared to the standard model (0 to 55°C).

  • Does this module require an external 24V DC power supply?

    Yes. You must provide 24V DC power to the terminal base to drive the analog output circuitry and the field devices. The module draws its logic power directly from the FLEX I/O backplane.

  • Which terminal bases are compatible with the 1794-OE4XT?

    This module typically mounts on 1794-TB2, 1794-TB3, or 1794-TBN terminal bases. For XT applications, ensure your selected terminal base and I/O adapter also support the extended temperature range.

  • Is this a genuine, factory-new unit?

    We guarantee that every 1794-OE4XT we ship is 100% Brand New and Original. The unit arrives in its original factory-sealed box, including authentic Allen Bradley serial numbers and manufacturer documentation.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more