Skip to content

What are you looking for?


You may also like

1756-RM2XT | Allen-Bradley | ControlLogix Enhanced Redundancy Module1756-RM2XT | Allen-Bradley | ControlLogix Enhanced Redundancy Module1756-RM2XT | Allen-Bradley | ControlLogix Enhanced Redundancy Module
1756-RM2XT | Allen-Bradley | ControlLogix Enhanced Redundancy Module
1756-RM2XT | Allen-Bradley | ControlLogix Enhanced Redundancy Module
1756-RM2XT | Allen-Bradley | ControlLogix Enhanced Redundancy Module

1756-RM2XT | Allen-Bradley | ControlLogix Enhanced Redundancy Module


Only 10 left - Selling fast

PRODUCT SKU : 1756-RM2XT

PRODUCT TYPE : Redundancy Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The 1756-RM2XT provides high-speed data synchronization between primary and secondary chassis in a ControlLogix redundancy system. As an "XT" (Extended Temperature) module, it features specialized components to withstand harsher environmental conditions than standard automation hardware. This module ensures bumpless switchover during a controller or chassis failure, maintaining continuous process operation in mission-critical applications. We supply this unit as 100% Brand New original hardware, ensuring your high-availability architecture operates with factory-certified precision and thermal resilience.

Technical Specifications

The 1756-RM2XT utilizes advanced fiber optic technology to maintain real-time chassis synchronization:

Parameter Specification
Manufacturer Allen-Bradley / Rockwell Automation
Module Type Enhanced Redundancy Module (XT Series)
Fiber Optic Support Single-channel (1)
Max Cable Length 4 Kilometers
Wavelength 1300 nm
Transmission Speed 1000 Mbps (1 Gbps)
Operating Temp -25°C to +70°C (-13°F to +158°F)*
Dimensions 5.51 x 4.41 x 5.71 inches
Weight 0.29 kg (0.64 lb)
Wire Size 20 AWG (for grounding)

Note: While standard specs list 0-60°C, the XT designation officially supports expanded ranges up to 70°C when installed in appropriate XT chassis.

Engineering Advantages

  • Long-Distance Synchronization: The 1300 nm fiber optic interface supports cable runs up to 4 kilometers. This allows engineers to physically separate redundant chassis in different fire zones or remote control rooms to protect against localized disasters.

  • Bumpless Switchover Performance: The 1000 Mbps (1 Gbps) transmission speed ensures near-instantaneous data mirroring. During a fault, the 1756-RM2XT facilitates a switchover so fast that the field actuators and remote I/O perceive no interruption in the control logic.

  • Extended Thermal Durability: The XT-series construction utilizes robust internal components and superior heat dissipation designs. This solves the pain point of hardware failure in non-climate-controlled cabinets or extreme outdoor environments.

  • Fiber Optic Isolation: By using fiber optics for chassis synchronization, the module provides total electrical isolation between redundant pairs. This eliminates ground loops and protects the control system from high-voltage surges or electromagnetic interference (EMI).

  • Simplified Redundancy Setup: The module handles complex synchronization tasks automatically. Once connected via fiber, it manages the scan list and data table mirroring without requiring manual code-heavy synchronization routines from the programmer.

FAQs

Q: Can I use the 1756-RM2XT with a standard 1756-RM2 module?

A: No. For a redundant pair to function correctly, both modules must share the same hardware series and firmware revision. We recommend using two 1756-RM2XT modules to ensure consistent thermal performance and synchronization timing.

Q: What type of fiber optic cable does this module require?

A: The 1756-RM2XT requires 62.5/125 micron multi-mode fiber optic cable. Ensure you use high-quality LC-style connectors to maintain the 1000 Mbps transmission integrity over long distances.

Q: Does this module require a separate power supply?

A: No. The 1756-RM2XT draws its power directly from the ControlLogix backplane. However, you must ensure the chassis power supply (such as a 1756-PA75R) provides sufficient current for the entire redundancy set.

Q: Why should I choose the "XT" version over the standard 1756-RM2?

A: Choose the 1756-RM2XT if your installation site experiences temperatures outside the standard 0-60°C range. The XT version specifically targets applications in oil and gas, mining, and remote pumping stations where environmental control is limited.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Marshalling cabinets serve as the crucial connection hub between field instruments and centralized processing units. In large DCS and PLC control system architectures, hundreds of multipair field cables run from local junction boxes to the central instrument equipment room. The marshalling cabinet houses field terminal blocks, surge arresters, intrinsic safety isolation barriers, and interposing relays. By segregating field field-wiring terminations from sensitive processor hardware, engineers protect expensive controller backplanes from high-voltage transients. Consequently, this modular separation dramatically streamlines maintenance workflows and simplifies system expansion.

Read more
Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Successful control system deployment begins with thoroughly reviewing manufacturer technical documentation. Controllers from major brands like Allen-Bradley, Siemens, and Schneider Electric feature unique terminal layouts. Engineers must verify voltage requirements before connecting power cables to prevent catastrophic equipment damage. Standard line connections require strict adherence to regional electrical codes and proper wire color coding. Furthermore, panel builders should always establish a robust low-impedance ground connection using at least 16-AWG copper conductor tied directly to the main plant grounding grid.

Read more
Demystifying Programmable Logic Controllers: Comprehensive Guide to PLC Classification and Selection in Industrial Automation

Demystifying Programmable Logic Controllers: Comprehensive Guide to PLC Classification and Selection in Industrial Automation

Modern industrial automation heavily relies on Programmable Logic Controllers (PLCs) to drive factory floor efficiency. Over my 15 years as an industrial automation expert working with DCS, TSI, and control systems, I have seen PLCs evolve into the central nervous system of modern manufacturing. Selecting the right controller requires a deep understanding of PLC types based on physical size, hardware architecture, and power supply configurations.

Read more