Configured for remanent memory retention and real-time clock buffering in ABB AC500 CPU architectures, the ABB TA521 1SAP180300R0001 (TA521 Adapter Cable) provides direct physical/electrical execution. The assembly houses an encapsulated lithium primary button cell (CR2450) that delivers continuous backup power directly to PM57x, PM58x, PM59x (excluding PM595), and PM56xx processors when the primary power supply is disconnected.

Hardware Specifications

Parameter Specification
Model TA521 1SAP180300R0001
Brand ABB
Origin Global Manufacturing Facilities
Weight 0.009 kg (Net)
Dimensions 100 mm x 8 mm x 170 mm
Operating Temp 0 deg C to +60 deg C
Power Consumption Passive battery draw (CR2450 Lithium Metal)
Battery Type Encapsulated Lithium Metal Button Cell CR2450
Degree of Protection IP20
Compatible CPUs AC500 V2 (PM57x, PM58x, PM59x - ex. PM595), AC500 V3 (PM56xx)
Hazardous Classification UN3090 Class 9 (Lithium Metal)

Backplane Bus Communication Velocity & I/O Density Scaling

The TA521 adapter cable attaches to designated CPU memory retention headers without impairing backplane bus communication velocity or backplane signal integrity. By offloading timekeeping and memory persistence tasks to an encapsulated CR2450 power source, the module ensures immediate application startup without data loss. Compact dimensions preserve overall rack clearance and maintain optimal cabinet I/O density scaling across AC500 control topologies, while firmware flash compatibility and real-time clock settings remain fully intact through main power power-down cycles.

Frequently Asked Questions

Q: Which specific CPU models are compatible with the TA521 adapter cable?

A: The TA521 interfaces directly with AC500 V2 processors (PM57x, PM58x, PM59x) and AC500 V3 processors (PM56xx). It is explicitly not compatible with PM595 CPUs.

Q: What are the primary functions maintained by the encapsulated battery cell?

A: The encapsulated CR2450 lithium cell maintains the processor real-time clock (RTC) and preserves contents within the remanent memory during power outage states.

Q: What precautions should be taken regarding shipping and transport regulation for the TA521?

A: The TA521 contains a lithium metal primary cell and is classified under dangerous goods designation UN3090 (Class 9), requiring compliance with standard transport handling regulations for lithium metal batteries.

Field Installation Guidelines

Observe the following field installation steps during replacement or system configuration:

  1. Power De-energization: Ensure the target AC500 CPU is safely powered down prior to accessing the battery connection slot.
  2. Connector Alignment: Align the TA521 adapter cable connector with the dedicated battery interface header on the CPU front housing.
  3. Insertion & Cable Routing: Insert the connector firmly into place until fully seated. Route the cable into the integrated retaining slot to avoid pinch points.
  4. Static Discharge Safety: Handle the cable assembly using standard electrostatic discharge (ESD) precautions to prevent damage to sensitive CMOS memory components.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Top 5 Operational Advantages of HMIs in Modern Factory Automation

Top 5 Operational Advantages of HMIs in Modern Factory Automation

HMIs bridge the gap between operators and complex industrial control networks. Modern factory automation relies on HMIs to deliver real-time visualization, precise control, and data analytics alongside PLC and DCS infrastructure. This technical guide explores five core operational benefits of deploying HMIs in manufacturing.
Read more
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more