Product Details

The ABB SPIPT800, also cataloged as the SPIPT800 Communication Module, operates as a dedicated hardware component for protocol translation and data bridging within INFI 90 and Symphony Plus automation network platforms. The module establishes direct communication paths between INFI-Net loop networks and Plant Network 800 (PN800) Ethernet buses to maintain deterministic signal exchange across control layers.

Hardware Specifications

Parameter Specification
Model SPIPT800
Brand ABB
Dimensions 139.7 mm x 88.9 mm x 215.9 mm
Operating Temp 0 deg C to +70 deg C
Power Consumption System Backplane Powered
Module Type Communication / Transfer Module
Redundancy Cable Redundant Pair (Requires SPK800-RCL1)
System Compatibility INFI 90 / Symphony Plus PN800 Architecture

Backplane Bus Communication Velocity & I/O Density Scaling

The SPIPT800 transfer module optimizes backplane bus communication velocity by buffering and routing cyclic data frames between legacy INFI-Net nodes and PN800 subnets. Its system architecture scales I/O density across distributed nodes without degrading loop response times. Integrated firmware flash compatibility ensures synchronized parameter mapping and deterministic packet transfer rates across attached process controllers.

Frequently Asked Questions

Q: What hardware component is required to establish a redundant SPIPT800 installation?

A: Redundant SPIPT800 module pairs require the SPK800-RCL1 redundancy cable to establish high-speed synchronization between primary and backup units.

Q: How does the SPIPT800 handle module power sourcing?

A: The module draws operating power directly from the mounting chassis backplane bus logic rails, eliminating the need for external power connections to the module fascia.

Q: Can the SPIPT800 operate in non-redundant standalone configurations?

A: Yes. The module can function as a single standalone transfer interface, provided the redundancy link port remains unpopulated and standard bus termination is applied.

Field Installation Guidelines

Observe the following engineering guidelines during installation and maintenance:

  1. Chassis Mounting: Insert the SPIPT800 module firmly into the designated rack slot along the enclosure guide rails until the backplane connectors fully seat. Tighten front panel retaining screws.
  2. Redundancy Cable Connection: For dual redundant pairs, connect the SPK800-RCL1 redundancy cable between the dedicated sync ports on both primary and secondary SPIPT800 modules.
  3. Network Shield Grounding: Ensure all communication cable drain wires and shields are grounded at the enclosure entry point to prevent high-frequency noise insertion.
  4. Hot-Swap Constraints: Before removing or replacing a module, confirm that redundant data paths are active and synchronized to prevent process communication interruptions.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more