The ABB NTAO02-AR-C, also cataloged as the NTAO02-AR-C Temperature and Humidity Control Module, operates as a dedicated hardware component for process sensor signal acquisition and analog output generation within ABB Bailey platforms.

Hardware Specifications

Parameter Specification
Model NTAO02-AR-C
Brand ABB
Origin Sweden
Weight 0.50 kg (1.1 lbs)
Dimensions 96 mm x 96 mm x 60 mm (3.8 in x 3.8 in x 2.4 in)
Operating Temp -20 to 60 deg C
Power Consumption 24 VDC Nominal
Input Signal Range 4-20 mA / 0-10 VDC
Output Signal Range 4-20 mA / 0-10 VDC
Accuracy +/-0.5%
Resolution 0.1%
Protection Rating IP65

Deterministic Network Integration and I/O Density Scaling

The NTAO02-AR-C module conditions analog process feedback into digital control loops across Profinet and EtherNet/IP deterministic networks. Onboard isolation stages prevent ground potential shifts from degrading channel measurement accuracy. Dynamic memory structures maintain uncorrupted backplane bus communication velocity during peak I/O density scaling, while hardware logic ensures full firmware flash compatibility during controller routine execution.

Frequently Asked Questions

Q: Does the NTAO02-AR-C support hot-swapping while the host panel backplane is energized?

A: No, system power must be isolated prior to removing or installing the module to avoid signal bus interruptions and transient overvoltage faults.

Q: How is the module mounted inside an enclosure?

A: The chassis accommodates mounting directly onto a standard 35 mm DIN rail or flush mounting through a designated panel cut-out.

Q: What protection level does the NTAO02-AR-C enclosure provide against dust and liquid ingress?

A: The front housing meets IP65 protection standards when properly sealed against the panel cutout surface.

Field Installation Guidelines

  • Isolate all 24 VDC power feeds and field wiring loops before performing module installation or terminal wiring.
  • Ensure proper terminal strip torque to maintain low-resistance contact on 4-20 mA and 0-10 VDC analog cable ends.
  • Ground all field cable shields at a single point on the enclosure functional earth bus to prevent ground loops.
  • Maintain minimum vertical clearance around the module housing to facilitate thermal convection inside the panel enclosure.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more