Skip to content

What are you looking for?


You may also like

ABB 3BHE014105R0001 5SHY3545L0020 IGCT ModuleABB 3BHE014105R0001 5SHY3545L0020 IGCT ModuleABB 3BHE014105R0001 5SHY3545L0020 IGCT Module
ABB 3BHE014105R0001 5SHY3545L0020 IGCT Module
ABB 3BHE014105R0001 5SHY3545L0020 IGCT Module
ABB 3BHE014105R0001 5SHY3545L0020 IGCT Module

ABB 3BHE014105R0001 5SHY3545L0020 IGCT Module


Only 10 left - Selling fast

PRODUCT SKU : 3BHE014105R0001 5SHY3545L0020 5SXE080166

PRODUCT TYPE : IGCT Modules

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The ABB 3BHE014105R0001 5SHY3545L0020, also cataloged as the 3BHE014105R0001 IGCT Module, operates as a dedicated hardware component for high-power semiconductor switching within power generation and electrical drive systems. The device provides direct electrical execution, managing a rated voltage of 3300 V and a rated current of 1800 A via an integrated Integrated Gate-Commutated Thyristor wafer. Encapsulated in a Press-Pack S4 housing with an integrated NTC 10 kOhm temperature sensor, the unit routes gate turn-on and turn-off pulses locally to regulate power flow across industrial energy platforms.

Hardware Specifications

Parameter Specification
Model 3BHE014105R0001 5SHY3545L0020 5SXE080166
Brand ABB
Origin Technical specifications determine final factory origin
Weight Heavy-duty press-pack assembly configuration dependent
Dimensions Press-Pack S4, 122 mm x 140 mm x 38 mm
Operating Temp -40 to +150 deg C (Junction Temperature)
Power Consumption Switch-dependent; Eon <= 650 mJ, Eoff <= 550 mJ @ 1500 V / 1800 A
Rated Voltage (VCES) 3300 V
Rated Current (IC) 1800 A @ 90 deg C
On-State Voltage Drop <= 1.5 V (typical)
Thermal Resistance Rth = 0.015 K/W (Junction-to-Case)
Isolation Voltage 12 kV AC, 1 min (50 Hz)
Integrated Monitoring NTC 10 kOhm temperature sensor, +/-1 deg C accuracy
Certifications UL 1557, IEC 60747-9

Profinet / EtherNet/IP Deterministic Networks Mapping

The high-power gate unit driver integrated within the module structures transient gating energy independently from external supervisory loops. Firmware flash compatibility across matching control boards maintains strict gate commutation velocity, ensuring that heavy dynamic load shifts do not propagate noise into the low-voltage control backplane bus. The localized thermal metric from the NTC 10 kOhm sensor can be digitized and mapped directly to Profinet / EtherNet/IP deterministic networks, enabling microsecond monitoring of switching energy boundaries during continuous 1800 A commutation cycles.

Frequently Asked Questions

Q: What are the backplane or external drive limitations regarding firmware flash compatibility for this IGCT gate unit?

A: The gate control board attached to the press-pack must match the exact hardware revision of the master excitation or drive controller. Mismatched firmware profiles will lead to incorrect gate pulse timing, violating the specified Eon and Eoff energy bounds and risking commutation failure.

Q: Can this module be hot-swapped while the primary 3300 V bus is de-energized but the 12 kV AC isolation boundaries are active?

A: No. The press-pack architecture relies on exact mechanical clamping force and absolute isolation from all voltage potentials before servicing. No part of the control wiring or gate interface can be disconnected while any auxiliary power or high-voltage lines are connected to the module group.

Field Installation Guidelines

  • Mechanical Clamping Pressure: Install the Press-Pack S4 module within an approved high-pressure clamping fixture to ensure symmetrical contact resistance across the upper and lower poles, maintaining the Rth 0.015 K/W thermal boundary.
  • Gate Driver Fiber Isolation: Route all optical gating lines through dedicated separation tracks to minimize risk of physical bending damage or distortion to the light signals.
  • NTC Signal Wiring: Connect the integrated NTC 10 kOhm monitoring terminals using shielded twisted-pair conductors, terminating the braid to earth ground at the cabinet entry bulkhead only.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
Mastering Modern Industrial Joystick Controls in Heavy Automation

Mastering Modern Industrial Joystick Controls in Heavy Automation

Industrial joysticks play a pivotal role in human-machine interaction across heavy material handling and mobile hydraulics. These tactile controllers translate complex operator movements into precise electrical signals for PLCs, motion controllers, and DCS networks. Consequently, selecting and installing the right joystick architecture ensures operator safety, reduces fatigue, and optimizes equipment performance.

Read more
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more