Skip to content

What are you looking for?


You may also like

ABB CI522AK04 3BSE018451R1 Advant Fieldbus 100 Communication InterfaceABB CI522AK04 3BSE018451R1 Advant Fieldbus 100 Communication InterfaceABB CI522AK04 3BSE018451R1 Advant Fieldbus 100 Communication Interface
ABB CI522AK04 3BSE018451R1 Advant Fieldbus 100 Communication Interface
ABB CI522AK04 3BSE018451R1 Advant Fieldbus 100 Communication Interface
ABB CI522AK04 3BSE018451R1 Advant Fieldbus 100 Communication Interface

ABB CI522AK04 3BSE018451R1 Advant Fieldbus 100 Communication Interface


Only 10 left - Selling fast

PRODUCT SKU : CI522AK04 3BSE018451R1

PRODUCT TYPE : Communication Modules

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The ABB CI522AK04 3BSE018451R1, also cataloged as the CI522AK04 Communication Module, serves as the primary CI522AK04 Communication Module utilized to execute Advant Fieldbus 100 bus topology routing across AC 400 or compatible controller platforms.

Hardware Specifications

Parameter Specification
Model CI522AK04 3BSE018451R1
Brand ABB
Origin Sweden
Weight 1.48 kg
Dimensions 265 mm D x 72 mm H x 148.5 mm W
Operating Temp Standard Industrial Limits (Refer to Technical Manual)
Power Consumption System-fed via Baseplate Interface
Protocol Support Advant Fieldbus 100 (AF 100)
Interface Kit Contents Full Coupling Termination Hardware
Battery Count 0
Compliance Non-RoHS Compliant; WEEE Category 5 (Small Equipment)

Deterministic Network Profiles and Token-Passing Latencies

The hardware manages cyclical and acyclic data exchanges over the AF 100 bus via a deterministic master-slave or token-passing scheme. To maintain synchronous communication velocities across large I/O density configurations, the onboard communication controller regulates frame traffic down to the millisecond layer. Any divergence in the transmission line impedence or firmware flash compatibility across active bus drops will degrade network determinism, generating framing errors in the central controller subsystem.

Frequently Asked Questions

Q: Does the CI522AK04 interface module support online hot-swap installation?

A: No. Physical removal or insertion of the module while the backplane bus is energized will break the electrical continuity of the AF 100 line. This results in transmission dropouts and causes the host controller to flag a bus communication timeout fault.

Q: How does a mismatch in bus termination affect the module's diagnostic status?

A: Incorrect or missing 150-ohm termination resistors at the ends of the AF 100 physical layer drop the differential voltage levels, causing data transmission packet timeouts. The module flags this state internally and stops cyclical updates across the backplane bus.

Field Installation Guidelines

  • Chassis Engagement: Align the interface guide rails with the designated slot positions on the subrack assembly. Push firmly until the rear connector block seats fully into the backplane, and lock the mechanical fastening screws.
  • AF 100 Bus Topography: Connect the trunk lines using approved twisted-pair or coaxial media configured for AF 100 layouts. Maintain strict physical separation between communication lines and high-voltage AC power paths to prevent electromagnetic cross-talk.
  • Shield Continuity Management: Ensure the incoming communication cable shields are grounded at the entry point of the enclosure frame using standard conductive ground clamps to dissipate stray high-frequency noise.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mastering Modern Industrial Joystick Controls in Heavy Automation

Mastering Modern Industrial Joystick Controls in Heavy Automation

Industrial joysticks play a pivotal role in human-machine interaction across heavy material handling and mobile hydraulics. These tactile controllers translate complex operator movements into precise electrical signals for PLCs, motion controllers, and DCS networks. Consequently, selecting and installing the right joystick architecture ensures operator safety, reduces fatigue, and optimizes equipment performance.

Read more
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more