Skip to content

What are you looking for?


You may also like

DSBC 173 57310001-KH ABBBus Repeater Slave ModuleDSBC 173 57310001-KH ABBBus Repeater Slave ModuleDSBC 173 57310001-KH ABBBus Repeater Slave Module
DSBC 173 57310001-KH ABBBus Repeater Slave Module
DSBC 173 57310001-KH ABBBus Repeater Slave Module
DSBC 173 57310001-KH ABBBus Repeater Slave Module

DSBC 173 57310001-KH ABB Bus Repeater Slave Module


Only 10 left - Selling fast

PRODUCT SKU : DSBC 173 57310001-KH

PRODUCT TYPE : Bus Repeater Slaves

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The ABB DSBC 173 57310001-KH, also cataloged as the DSBC 173 Bus Repeater Slave, operates as a dedicated hardware component for localized control logic execution within Advant OCS networks. Configured for signal amplification and electrical isolation across extended bus topologies, the assembly reconstructs degraded transmission frames to provide direct physical/electrical execution of real-time communication protocols.

Hardware Specifications

Parameter Specification
Model DSBC 173 57310001-KH
Brand ABB
Origin Sweden / Germany (Standard series production baseline)
Weight 0.43 kg
Dimensions 150 mm x 100 mm x 70 mm
Communication Protocols DeviceNet, CANopen
Number of Channels 10
Input Voltage 24 VDC
Output Current 12 mA
Power Consumption < 0.5 W
Connector Type M8 x 0.8 mm pitch
Operating Temp -20 to +55 deg C
Regulatory Status RoHS exemption under 2011/65/EU regulations
Product Type Bus Repeater Slaves

Profinet / EtherNet/IP Deterministic Networks and I/O Density Scaling

The internal signal-conditioning circuitry of the ABB DSBC 173 57310001-KH is calibrated to match strict backplane bus communication velocity parameters. When bridging field segments to higher-level industrial topologies, such as Profinet or EtherNet/IP deterministic networks, the module handles cross-network data packets without increasing propagation latencies. The 10-channel layout isolates electrical noise vectors during periods of high I/O density scaling, keeping data frame transitions accurate and maintaining local node operation within the boundaries of host controller firmware flash compatibility requirements.

Frequently Asked Questions

Q: Is hot-swapping or live extraction of the M8 connector plugs supported while the module is powered?

A: No. The DSBC 173 does not feature active live-insertion isolation circuitry. Removing or re-inserting the communication interfaces while the 24 VDC supply or bus segments are energized can cause electrical transients, causing immediate data frame corruption or permanent physical trace failure on the communication paths.

Q: How is an internal channel signal degradation or transmission fault diagnosed?

A: Diagnostic states must be verified through the central host controller register map. If a bus link drops or registers CRC errors, check the physical 24 VDC input tolerances and confirm that the overall cable length across the M8 connectors does not violate protocol distance specifications.

Field Installation Guidelines

  1. ESD Grounding Requirements: Technical field personnel must use a properly calibrated and grounded electrostatic discharge (ESD) wrist strap prior to opening the protective packaging or handling the internal circuit boards to prevent dielectric micro-circuit damage.
  2. Mechanical Mounting and Fastening: Mount the 0.43 kg housing securely inside the control enclosure. When mating the M8 x 0.8 mm pitch connectors, torque the connections to factory specification limits to avoid loose mechanical contacts and ensure proper environmental sealing.
  3. Control Cable Routing Isolation: Route all incoming DeviceNet and CANopen communication lines inside separate low-voltage wireways. Keep a physical separation distance of at least 100 mm from high-voltage AC conductors and motor drive cabling to protect against electromagnetic interference.
  4. Environmental Exposure Limits: Install the module inside an IP 54 or better enclosure that eliminates ambient moisture condensation, airborne conductive dust, and corrosive vapors to prevent tracking short-circuits.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more
Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Factory Acceptance Testing (FAT) and Site Acceptance Testing (SAT) serve as critical quality assurance gateways in complex industrial control systems. Both procedures verify that programmable logic controllers (PLCs), distributed control systems (DCS), and associated field devices meet strict functional specifications. However, executing these tests effectively requires clear delineation between off-site staging and final field commissioning.

Read more