Product Details

The ABB DSRA 110 21660559-H, also cataloged as the DSRA 110 Terminal Carrier Kit, operates as a dedicated hardware component for mechanical mounting bar structural support and hardware positioning within ABB control cabinet enclosures.

Hardware Specifications

Parameter Specification
Model DSRA 110
Part Number 21660559-H
Brand ABB
Product Type Terminal Carrier Kits
Component Type Mounting Bar for Connection Units and Modems
Origin Sweden
Weight 1.225 kg
Dimensions 19" x 3S
Operating Temp -20 to +60 deg C
Power Consumption Passive structural assembly (0 W)
Customs Tariff Number 85389091
WEEE Compliance Product Not in WEEE Scope

Subrack Structural Frame Alignment and High I/O Density Scaling

Engineered for 19-inch subrack integration, the carrier bar accepts connection units and modem modules while optimizing physical layout efficiency. Structural metal construction ensures chassis ground continuity across mounted field termination interfaces, supporting high I/O density scaling inside control cabinets. Solid metallic mechanical fastening prevents physical displacement and vibration decoupling, protecting backplane bus interface cables from stress or strain.

Frequently Asked Questions

Q: Does the DSRA 110 terminal carrier kit draw electrical power from the backplane?

A: No, the DSRA 110 is a passive mechanical mounting bar assembly with zero electrical power consumption.

Q: Can individual mounting bars be replaced without replacing the entire carrier kit assembly?

A: Yes, the structural mounting bar is available as an individual component under part number 21660566-22.

Q: How is chassis earth grounding achieved across mounted terminal modules?

A: Metallic contact surfaces on the carrier kit bond mechanically to the main enclosure frame when retaining fasteners are tightened, establishing earth grounding continuity.

Field Installation Guidelines

  1. Verify subrack cabinet dimensions match the 19" x 3S mounting specification before positioning the carrier kit.
  2. Align the mounting bar side flanges with the cabinet rack guide holes and insert M6 fixing bolts.
  3. Torque all mounting screws to standard engineering specifications to secure structural rigidity and chassis ground contact.
  4. Mount connection units or modems onto the carrier bar, ensuring locking latches are fully engaged.
  5. Maintain a minimum physical separation distance of 200 mm between low-voltage modem/signal wiring and AC power distribution cables.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more