Skip to content

What are you looking for?


You may also like

Yokogawa AMM31T CENTUM RTD Input Multiplexer Module | 16-ChannelYokogawa AMM31T CENTUM RTD Input Multiplexer Module | 16-ChannelYokogawa AMM31T CENTUM RTD Input Multiplexer Module | 16-Channel
Yokogawa AMM31T CENTUM RTD Input Multiplexer Module | 16-Channel
Yokogawa AMM31T CENTUM RTD Input Multiplexer Module | 16-Channel
Yokogawa AMM31T CENTUM RTD Input Multiplexer Module | 16-Channel

Yokogawa AMM31T CENTUM RTD Input Multiplexer Module | 16-Channel


Only 10 left - Selling fast

PRODUCT SKU : AMM31T

PRODUCT TYPE : RTD Input Module

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Yokogawa AMM31T functions as a high-density RTD Input Multiplexer Module specifically engineered for the Yokogawa Distributed Control System (DCS) platform. This module aggregates temperature data from up to 16 independent RTD sensors (such as Pt100 or Pt1000), sequentially routing precision signals through the backplane bus to the central controller. By consolidating multiple temperature points into a single rack-mounted unit, it significantly reduces the wiring complexity and hardware footprint of large-scale thermal monitoring networks. We supply this module as 100% Brand New and original, ensuring factory-sealed accuracy for your critical process loops.

Technical Specifications

The AMM31T utilizes high-speed scanning and robust multi-pin connections to maintain signal integrity across diverse temperature ranges.

  • Manufacturer: Yokogawa

  • Module Type: RTD Input Multiplexer

  • Compatible Sensors: Pt100, Pt1000 (Resistance Temperature Detectors)

  • Channel Capacity: Up to 16 channels (system configuration dependent)

  • Measurement Range: -200°C to +600°C

  • Scanning Speed: ≤ 50 ms per channel (Typical)

  • Interface: Multi-pin Board-Edge Connectors

  • Communication: Backplane Bus Integration

  • Installation: Rack-mounted Plug-in design

  • Operating Temperature: 0°C to 55°C

  • Condition: 100% Brand New and Original

Engineering Advantages

The AMM31T addresses specific technical challenges in industrial thermal management through precision hardware design:

  • High-Density Signal Consolidation: Managing 16 channels in a single plug-in module drastically reduces the physical space required in the I/O nest. This allows engineers to expand temperature monitoring capabilities without upgrading to larger, more expensive control cabinets.

  • Deterministic Scanning Performance: The module achieves a typical scanning time of 50 ms per channel. This rapid multiplexing ensures the DCS receives near-real-time temperature updates, which is critical for maintaining stability in fast-reacting chemical or steam processes.

  • Seamless Backplane Integration: The board-edge connector design allows the AMM31T to snap directly into standard Yokogawa DCS racks. This plug-and-play architecture eliminates complex internal wiring and reduces the risk of connection errors during system commissioning.

  • Robust Noise Immunity: Integrated signal conditioning circuits filter out electromagnetic interference (EMI) often found in power generation and heavy industrial environments. This ensures that long-distance RTD lead wires do not introduce significant measurement drift or jitter into the process variables.

FAQs

Which RTD types does the AMM31T support?

The module primarily interfaces with standard Pt100 and Pt1000 sensors. It provides accurate resistance-to-digital conversion across a wide range of -200°C to +600°C, making it suitable for both cryogenic and high-heat applications.

Can I install the AMM31T in an existing CENTUM rack?

Yes. The module features a standard modular plug-in design. It fits natively into existing Yokogawa DCS racks and communicates via the standard backplane bus, requiring no additional hardware modifications.

What maintenance or calibration does the AMM31T require?

We deliver each unit with factory-standard calibration. While the robust industrial design maintains stability over long periods, we recommend a secondary verification of the loop accuracy after installation to compensate for lead-wire resistance in the field.

How does this module benefit large-scale plants?

Plants in the chemical, pharmaceutical, and power sectors utilize the AMM31T to centralize their temperature monitoring. The multiplexing capability lowers the "per-channel" cost of I/O hardware while providing the high reliability demanded by 24/7 continuous operations.

 

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Marshalling cabinets serve as the crucial connection hub between field instruments and centralized processing units. In large DCS and PLC control system architectures, hundreds of multipair field cables run from local junction boxes to the central instrument equipment room. The marshalling cabinet houses field terminal blocks, surge arresters, intrinsic safety isolation barriers, and interposing relays. By segregating field field-wiring terminations from sensitive processor hardware, engineers protect expensive controller backplanes from high-voltage transients. Consequently, this modular separation dramatically streamlines maintenance workflows and simplifies system expansion.

Read more
Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Successful control system deployment begins with thoroughly reviewing manufacturer technical documentation. Controllers from major brands like Allen-Bradley, Siemens, and Schneider Electric feature unique terminal layouts. Engineers must verify voltage requirements before connecting power cables to prevent catastrophic equipment damage. Standard line connections require strict adherence to regional electrical codes and proper wire color coding. Furthermore, panel builders should always establish a robust low-impedance ground connection using at least 16-AWG copper conductor tied directly to the main plant grounding grid.

Read more
Demystifying Programmable Logic Controllers: Comprehensive Guide to PLC Classification and Selection in Industrial Automation

Demystifying Programmable Logic Controllers: Comprehensive Guide to PLC Classification and Selection in Industrial Automation

Modern industrial automation heavily relies on Programmable Logic Controllers (PLCs) to drive factory floor efficiency. Over my 15 years as an industrial automation expert working with DCS, TSI, and control systems, I have seen PLCs evolve into the central nervous system of modern manufacturing. Selecting the right controller requires a deep understanding of PLC types based on physical size, hardware architecture, and power supply configurations.

Read more