Skip to content

What are you looking for?


You may also like

Yokogawa ADV551-P50 CENTUM VP 32-Channel Digital Output ModuleYokogawa ADV551-P50 CENTUM VP 32-Channel Digital Output ModuleYokogawa ADV551-P50 CENTUM VP 32-Channel Digital Output Module
Yokogawa ADV551-P50 CENTUM VP 32-Channel Digital Output Module
Yokogawa ADV551-P50 CENTUM VP 32-Channel Digital Output Module
Yokogawa ADV551-P50 CENTUM VP 32-Channel Digital Output Module

Yokogawa ADV551-P50 CENTUM VP 32-Channel Digital Output Module


Only 10 left - Selling fast

PRODUCT SKU : ADV551-P50

PRODUCT TYPE : Digital Output Module

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Yokogawa ADV551-P50 serves as a high-density, ruggedized discrete control interface for the CENTUM VP Distributed Control System (DCS). This 32-channel module executes switching commands to manage field actuators such as solenoid valves, interposing relays, and signaling lamps. Equipped with the "P" functional suffix, this module supports advanced pulse width and time-proportional output functions. The "50" designation indicates that the module features G3-level corrosive resistance, making it the definitive choice for facilities exposed to aggressive atmospheric contaminants.

Condition: 100% Brand New and Original Factory Sealed.

Part Number Breakdown: ADV551-P50

Yokogawa utilizes a structured coding system to define environmental protection and connection styles:

  • ADV551: Digital Output Module (32-channel, 24 V DC, Isolated).

  • -P: Equipped with Pulse Width Output and Time-Proportional Output functions.

  • 5: With G3 Corrosive Resistance

  • 0: Basic type hardware specification for universal interface logic.

Technical Specifications

The ADV551-P50 provides high-speed switching and environmental hardening for critical control loops.

  • Number of Channels: 32, isolated

  • Rated Output Voltage: 24 V DC

  • Maximum Load Current: 100 mA per channel (at 26.4 V DC)

  • Response Time (Status): 3 ms or less

  • Response Time (Pulse): 10 ms or less

  • Environmental Protection: ISA Standard S71.04 Class G3

  • Isolation Type: Optical isolation between system and field

  • Current Consumption: 500 mA (at 5 V DC)

Engineering Advantages

  • G3-Rated Corrosive Resistance: The ADV551-P50 features specialized conformal coating on its internal circuit boards. This prevents silver and copper corrosion caused by hydrogen sulfide and other aggressive gases, significantly extending the module's lifespan in unconditioned industrial environments like refineries and wastewater plants.

  • Hardware-Based Pulse Modulation: The module executes time-proportional control cycles internally. This offloads timing-critical tasks from the main controller CPU, ensuring consistent pulse widths for dosing or heating applications regardless of the DCS logic scan time.

  • Maximized Rack Density: Processing 32 outputs within a single slot maximizes I/O density. This allows engineers to utilize smaller control cabinets and fewer subracks, lowering the total cost of installation and cooling.

  • Ultra-Fast Signal Execution: A 3 ms response time for status outputs ensures nearly instantaneous command delivery. This performance is vital for high-speed interlocking and sequence-of-events (SOE) applications where millisecond precision prevents mechanical damage.

  • Industrial-Grade Optical Isolation: Optical isolation protects the internal DCS bus from field-side electrical surges and ground loops. This architecture ensures that a localized short circuit on a field actuator does not propagate to the central safety logic.

FAQs

  • Can the ADV551-P50 replace a standard ADV551-P00 model?

    Yes. The P50 version offers identical functionality and pulse features but adds G3 environmental protection. It is a recommended upgrade if your control room is located in a corrosive area.

  • Does the ADV551-P50 require an external field power supply?

    Yes. You must provide a 24 V DC external supply to drive the output loads. The module switches this power across the 32 channels via its isolated transistor array.

  • What is the difference between ADV551-P50 and ADV551-P53?

    The P50 is the basic G3-rated version, while the P53 is a later hardware revision. Both share the same core specifications and environmental ratings, though the P53 may contain updated internal sub-components for improved thermal efficiency.

  • Is the ADV551-P50 compatible with redundant I/O?

    Yes. When used with a redundant-capable baseplate, you can install these modules in pairs. The system maintains continuous control even if one module requires replacement or experiences a fault.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more