Product Details

Technical Overview

The AAI143-H00/A4S00 is a high-density, isolated analog input module designed for the Yokogawa CENTUM VP distributed control system. This module supports 16 channels of 4 to 20 mA signals, providing robust data acquisition with built-in HART digital communication capabilities. Unlike non-isolated variants, this unit features a 1500 V AC withstanding voltage between the input channels and the system logic, ensuring maximum protection against ground loops and electrical interference in harsh industrial environments.

Engineered for precision, the AAI143-H00/A4S00 offers an ultra-fast data update period of 10 ms. It is highly versatile, allowing engineers to configure each individual channel for either 2-wire or 4-wire transmitter types via physical setting pins, making it a flexible solution for diverse field instrumentation needs.

Detailed Specifications

  • Model Number: AAI143-H00/A4S00

  • Input Configuration: 16-channel current input (Fully isolated)

  • Signal Range: 4 to 20 mA DC (Standard process signals)

  • Digital Communication: HART Protocol supported (H-prefix)

  • Terminal Interface: Includes A4S00 Pressure Clamp Terminal Block

  • Measurement Accuracy: ±16 µA (High-resolution processing)

  • Update Cycle: 10 ms (Real-time monitoring)

  • Dielectric Strength: 1500 V AC for 1 minute (Input-to-System)

  • Transmitter Power: 19.0 V DC (at 20 mA) to 25.5 V DC (at 0 mA)

  • Input Impedance (Power ON): 270 Ω (at 20 mA) up to 350 Ω (at 4 mA)

  • Input Impedance (Power OFF): ≥ 500 kΩ (High-impedance safety state)

  • Temperature Stability: ±16 µA per 10 °C fluctuation

  • Power Requirements: 230 mA (5 V DC) and 540 mA (24 V DC)

  • Connection Type: Pressure clamp, MIL connector, or KS1 dedicated cable

  • Unit Weight: Approximately 0.3 kg (Excluding terminal block)

Channel Configuration and Wiring

The module is designed for granular control over field wiring. Each channel can be independently toggled between 2-wire (loop-powered) and 4-wire (externally powered) modes using internal jumper pins. The A4S00 suffix denotes that this specific package includes the pressure clamp terminal block, allowing for direct field wiring without requiring separate termination boards.

Comparison: Isolated vs. Non-Isolated Modules

Feature AAI143 (Isolated) AAI141 (Non-Isolated)
Grounding Individual channel protection Common ground
Noise Rejection Superior (High CMT) Moderate
System Protection 1500V Isolation Minimal
Best For Long cable runs / High noise Local / Low-cost loops

Frequently Asked Questions

  • What does the 'H' in the part number signify?

    The 'H' indicates that the module supports HART digital communication, allowing for remote diagnostics and configuration of field instruments through the analog loop.

  • Is the terminal block included?

    Yes, the A4S00 code confirms this module is shipped with the Pressure Clamp Terminal Block.

  • Can I mix 2-wire and 4-wire transmitters on one module?

    Yes. Each of the 16 channels is individually configurable using the onboard setting pins.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Top 5 Operational Advantages of HMIs in Modern Factory Automation

Top 5 Operational Advantages of HMIs in Modern Factory Automation

HMIs bridge the gap between operators and complex industrial control networks. Modern factory automation relies on HMIs to deliver real-time visualization, precise control, and data analytics alongside PLC and DCS infrastructure. This technical guide explores five core operational benefits of deploying HMIs in manufacturing.
Read more
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more