Product Description

The IC200PWR002 is a DC power supply module from GE Fanuc’s VersaMax series, designed to provide reliable and stable power for industrial control applications. It delivers dual output voltages suitable for PLCs and related I/O modules, with robust protection features to ensure safe operation.

Technical Specifications

  • Manufacturer: GE Fanuc

  • Model / Part Number: IC200PWR002

  • Product Type: Power Supply Module

  • Condition: New & Original in Factory Packing

  • Warranty: 12 Months Factory Warranty

  • Input Voltage: 18 to 30 VDC (24 VDC nominal)

  • Input Power: 11 W

  • Holdup Time: 10 ms

  • Inrush Current:

    • 20 A at 24 VDC

    • 25 A at 30 VDC

  • Output Voltages: 5 VDC, 3.3 VDC

  • Output Current:

    • Total: 1.5 A maximum

    • 3.3 VDC: 1.0 A maximum

    • 5 VDC: (1.5 A minus 3.3 V load) maximum

  • Protection: Short circuit, overload, reverse polarity

Features

  • Compact design for easy integration with VersaMax controllers

  • Provides stable dual-output DC power for logic and peripheral circuits

  • Integrated protection mechanisms for reliable industrial operation

  • High inrush current handling for smooth start-up under load

Applications

  • Powering VersaMax PLCs and I/O modules

  • Industrial control panels requiring regulated 5V and 3.3V outputs

  • Replacement or upgrade for existing DC power supply units

FAQ / Comparison

Q: Is the IC200PWR002 compatible with all VersaMax modules?
A: Yes, it is fully compatible with standard VersaMax I/O and controller systems.

Q: Does the module include internal fuses?
A: No, external circuit protection is recommended for safety.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more
Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Emergency stop (E-Stop) pushbuttons serve as vital safety devices in factory automation and process control plants. Functional safety standards mandate normally-closed (NC) contact blocks to ensure fail-safe operation during wiring breaks or power outages. However, mechanical degradation over time can trigger unexpected spurious trips, halting production lines without an actual emergency. Understanding the underlying causes of mechanical contact failure allows automation engineers to implement robust, fault-tolerant safety circuits.

Read more
Redundant Automation Systems: Maximizing Uptime in Critical Control Applications

Redundant Automation Systems: Maximizing Uptime in Critical Control Applications

Industrial automation relies on continuous operational stability to prevent catastrophic downtime and financial loss. While standard dictionary definitions treat redundancy as superfluous, industrial engineers consider redundant control architectures indispensable for high-availability systems. Implementing backup hardware ensures seamless takeover during primary equipment failures, protecting critical infrastructure across manufacturing and process industries.

Read more