Only 10 left - Selling fast

PRODUCT SKU : UR6AH

PRODUCT TYPE : Digital I/O Module

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview  

The GE UR6AH Digital I/O Module is designed for integration into the Multilin Universal Relay (UR) series. It provides eight digital inputs and two Form A/C relay outputs, enabling precise monitoring and control functions in electrical protection and automation systems.

Technical Specifications

  • Manufacturer: General Electric Multilin

  • Model: UR6AH

  • Type: Digital Input/Output Module

  • Inputs: 8 digital (binary) inputs, typically 24 VDC

  • Outputs: 2 relay outputs, Form A/C, rated up to 6 A

  • Communication Protocols: Modbus, IEC 61850

  • Mounting: DIN rail compatible

Key Features

  • Eight digital inputs for monitoring electrical signals

  • Two Form A/C relay outputs with 6 A maximum current rating

  • Supports industry-standard communication protocols for system integration

  • DIN rail mounting for simplified installation

  • Certified for compliance with international standards

Applications

  • Electrical protection relays requiring digital input/output expansion

  • Substation automation systems

  • Industrial control systems with Modbus or IEC 61850 communication

  • Power system monitoring and control

FAQ

  • Q: How many inputs and outputs does the UR6AH provide?  A: It offers 8 digital inputs and 2 Form A/C relay outputs.

  • Q: What is the maximum current rating for the relay outputs?  A: Each relay output supports up to 6 A.

  • Q: Which communication protocols are supported?  A: The UR6AH supports Modbus and IEC 61850.

  • Q: How is the module mounted?  A: It is DIN rail mountable for easy installation.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more