Skip to content

What are you looking for?


You may also like

GE Fanuc D25-0157-000003 Measurement and Control DeviceGE Fanuc D25-0157-000003 Measurement and Control DeviceGE Fanuc D25-0157-000003 Measurement and Control Device
GE Fanuc D25-0157-000003 Measurement and Control Device
GE Fanuc D25-0157-000003 Measurement and Control Device
GE Fanuc D25-0157-000003 Measurement and Control Device

GE Fanuc D25-0157-000003 Measurement and Control Device


Only 10 left - Selling fast

PRODUCT SKU : D25-0157-000003

PRODUCT TYPE : Industrial Controllers

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The GE Fanuc D25-0157-000003, also cataloged as the D25 Measurement and Control Device, operates as a dedicated hardware component for specific technical task execution within industrial automation and network platforms. The component ingests high-accuracy electrical telemetry across integrated AC current, DC current, and DC voltage physical interface nodes. By calculating waveforms from multi-range CT links and instrument loops, the module services localized digital fault recording (DFR) and real-time regulation routines over active internal processing buses.

Hardware Specifications

Parameter Specification
Model D25-0157-000003
Brand GE Fanuc
Origin Technical specifications determine factory origin
Weight Internal hardware option selection dependent
Dimensions Standard D25 series chassis envelope requirements apply
Operating Temp Industrial grade environmental classification
Power Consumption Base processor draw plus active measuring channel configuration loads
Nominal CT Input Options 1 A rms or 5 A rms
AC Measurement Range 2% to 1600% of nominal; 2% to 4200% (asymmetrical) for DFR/protection
Thermal Overload Limits 4x nominal continuous; 30x nominal for 10 seconds; 100x nominal for 1 second; 10-minute duty cycle for parameters exceeding 4x nominal
AC Accuracy Metrics Accuracy: +/-0.5% to +/-0.3% of nominal; Frequency: +/-0.03 Hz; Phase Angle: +/-0.5 deg
DC Current Ranges +/-1 mA, +/-5 mA, +/-10 mA, +/-20 mA nominal
DC Current Accuracy +/-0.10% of full scale
DC Voltage Input Span Nominal: +/-5 Vdc; Measurement range: +/-6 Vdc
DC Voltage Accuracy +/-0.05% of full scale

Profinet / EtherNet/IP Deterministic Networks Integration

The module manages input scaling through its internal analog-to-digital matrix, utilizing fixed software filtering blocks to maintain firmware flash compatibility across concurrent operating cycles. High-density I/O registers serialize the +/-20 mA DC current loops and +/-6 Vdc voltage inputs into the memory map, isolating transient electrical noise from the primary processor backplane communication channel. This architectural separation preserves deterministic communication performance, preventing host communication packet peaks from delaying the 1 ms fault-recording triggers managed by the AC protection circuits.

Frequently Asked Questions

Q: How is the 4200% asymmetrical AC current measurement range managed by the DFR firmware without causing memory overflows?

A: The onboard analog-to-digital conversion matrix reserves dedicated high-headroom registers for transient surge inputs. When an asymmetrical fault step occurs, the internal scaling algorithms automatically track the over-range parameter without impacting firmware flash compatibility or disrupting concurrent DC loop sampling.

Q: Can the CT input terminals be disconnected while the primary power lines are under load?

A: No. Disconnecting active CT loops causes high-voltage open-circuit transients that can destroy the low-burden input resistors. The secondary current paths must be externally shorted or fully isolated before servicing any analog connector blocks on the D25-0157-000003.

Field Installation Guidelines

  • Earthing and Grounding Frame: Bond the metal chassis ground screw directly to the main cabinet copper ground bus bar using a low-impedance grounding cable before routing any instrumentation lines.
  • AC Input Shielding: Run all AC current transformer connections through dedicated twisted-shielded pairs, terminating the shield grounding braid strictly at the enclosure wall plate to block inductive interference.
  • Low-Voltage Cable Trailing: Route the +/-5 Vdc voltage and low-current DC signal lines in distinct wiring ducts isolated from primary high-voltage AC switches and inductive control relay circuitry.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mastering the Siemens PLC Scan Cycle: How the CPU Executes Automation Programs

Mastering the Siemens PLC Scan Cycle: How the CPU Executes Automation Programs

Industrial automation relies heavily on programmable logic controllers (PLCs) to manage complex manufacturing processes. Many engineers dive straight into programming without mastering the underlying architecture. However, understanding how a PLC CPU executes a program ensures reliable system design. Therefore, mastering the scan cycle optimizes both performance and troubleshooting in modern control systems.

Read more
How to Connect to Siemens S7 PLCs: 5 Essential Communication Methods

How to Connect to Siemens S7 PLCs: 5 Essential Communication Methods

Establishing a reliable hardware link between a programming terminal and a Siemens SIMATIC controller is essential for engineering workflows. Field engineers rely on distinct physical layers, ranging from legacy serial connections to high-speed Industrial Ethernet protocols. Modern factory automation environments prioritize fast data transfer and seamless driver integration. Selecting the correct connection method simplifies program downloads, online monitoring, and system troubleshooting in complex control systems.

Read more
Will PLCs Become Obsolete? The Future of Control Systems in Industry 4.0

Will PLCs Become Obsolete? The Future of Control Systems in Industry 4.0

Modern manufacturing is undergoing a rapid technological transformation driven by Industry 4.0 innovations. Technologies like Artificial Intelligence (AI), Machine Learning (ML), and the Industrial Internet of Things (IIoT) are dominating discussions across the factory automation sector. Consequently, many engineers wonder if these advanced digital tools will eventually replace traditional Programmable Logic Controllers (PLCs). However, evaluating the core physics of industrial operations reveals a very different reality for control systems.

Read more