The Yokogawa TERT, also cataloged as the TERT Terminal Blocks Module, operates as a dedicated hardware component for 16-point RTD input signal termination and field wiring interfacing within Yokogawa control system racks.

Hardware Specifications

Parameter Specification
Model TERT
Brand Yokogawa
Origin Japan
Contact Points 16 points
Terminal Type M4 screws
Insulation Resistance Minimum 100 Mohm (500 V DC)
Withstanding Voltage 500 V AC
Hazardous Area Rating CSA Non-Incendive certification
Weight Approx. 1.8 kg
Dimensions Standard Yokogawa Terminal Module Chassis
Operating Temp 0 to 50 deg C
Power Consumption Passive Component (Zero Power Dissipation)

Yokogawa RTD Signal Conditioning & CJC Channel Isolation

The TERT module routes 16-channel RTD temperature sensor connections through heavy-duty M4 screw terminals to backplane A/D converter cards. Mechanical separation between input channels guarantees minimum 100 Mohm insulation resistance, providing robust channel-to-channel isolation. The terminal structure maintains signal linearity for RTD resistance variations while preventing common-mode noise interference across sensitive process control loops.

Frequently Asked Questions

Q: Does the TERT terminal block module draw operating current from the system backplane?

A: No, the TERT module functions strictly as a passive wiring interface for field RTD sensor leads and consumes zero backplane power.

Q: What environmental safety ratings apply to field installation of the TERT terminal module?

A: The TERT module holds CSA Non-Incendive certification, permitting installation in designated Class I, Division 2 hazardous locations when wired per agency control drawings.

Field Installation Guidelines

Mount the TERT terminal blocks module firmly onto its assigned chassis slot, securing all retaining fasteners to establish mechanical stability and cabinet grounding continuity. Strip 3-wire or 4-wire RTD field conductors to standard lengths and clamp them under the M4 terminal screws using recommended torque limits. Route low-level RTD signal wiring through separate cable ducts isolated from AC power conductors, and terminate cable shields at a single ground point on the panel earth bar.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Redefining Control Systems: The Rise of Flexible I/O Modules in Industrial Automation

Redefining Control Systems: The Rise of Flexible I/O Modules in Industrial Automation

Conventional input-output architectures often limit engineering agility and inflate long-term inventory costs. Today, Flexible Input/Output Modules (FIOM) are transforming how control system engineers design, commission, and maintain automation infrastructure. By allowing individual channel software configuration, FIOM technology bridges the gap between rigid hardware design and dynamic plant requirements.

Read more
Understanding Modern SCADA Systems: Architecture, Communication Topologies, and Industrial Applications

Understanding Modern SCADA Systems: Architecture, Communication Topologies, and Industrial Applications

Supervisory Control and Data Acquisition (SCADA) systems form the digital backbone of modern industrial automation. They collect critical field data, transmit signals across vast distances, and empower plant operators with real-time process visibility. Across modern infrastructures, SCADA solutions streamline centralized control and maintain continuous operational uptime.

Read more
Understanding OPC Servers in Modern Industrial Automation: Principles, Architecture, and Applications

Understanding OPC Servers in Modern Industrial Automation: Principles, Architecture, and Applications

In industrial automation, connecting physical hardware with high-level software remains a primary operational challenge. Factories utilize programmable logic controllers (PLCs), distributed control systems (DCS), human-machine interfaces (HMIs), and smart sensors from diverse vendors. These devices often speak different proprietary protocols. Open Platform Communications (OPC) servers solve this interoperability challenge by standardizing how data flows across factory networks.

Read more