Product Description

The TC-FIAH81 is a high-speed analog acquisition module engineered for the Honeywell Experion PKS and C200 controller architectures. Designed for high-level signal processing, this module provides eight single-ended inputs capable of interfacing with a variety of industrial sensors. It features a highly efficient 256 µs conversion rate across all channels, making it suitable for dynamic control loops where rapid data refreshing is essential. The unit is optimized for 16-bit data formatting (left-justified 2's complement), ensuring seamless integration with the system's internal processing logic while maintaining a low thermal footprint.

Technical Specifications

  • Module Identification: TC-FIAH81

  • Input Density: 8 Single-Ended Channels

  • Configurable Signal Ranges: Voltage (±10V, 0-10V) or Current (0-20mA, 4-20mA)

  • Conversion Resolution: 12-bit unipolar; 11-bit plus sign bipolar

  • Current Sensitivity: 5.13 µA per count

  • Input Impedance (Voltage): 100 kΩ

  • Input Impedance (Current): 238 Ω

  • Global Update Rate: 256 µs for all active channels

  • System Isolation: 850 VDC (User-to-System); No channel-to-channel isolation

  • Calibration Accuracy: ±0.20% Full Scale @ 25°C

  • Continuous Overload Protection: 30V or 32mA (single channel limit)

  • Power Consumption: Maximum 3 W @ 31.2V DC

  • Thermal Output: 10.2 BTU/hr

  • Operating Footprint: 51 mm x 178 mm x 356 mm

  • Storage Environment: -40°C to +85°C

Operational Application

The TC-FIAH81 is a versatile choice for monitoring standard process variables such as pressure, temperature, and flow rate where high-level signals are pre-conditioned by field transmitters. Its single-ended design is most effective in environments with a common signal ground, allowing for high-density I/O integration within a compact 51 mm wide chassis. For mission-critical loops, the module’s integrated overload protection prevents field-side surges from damaging the internal circuitry.

Frequently Asked Questions

  • Does this module support differential input wiring?

    The TC-FIAH81 is specifically designed for single-ended inputs. For applications requiring differential wiring to reduce common-mode noise, an alternative module like the TC-FXX series should be considered.

  • Is there individual channel isolation?

    While the module provides 850 VDC isolation between the field wiring and the controller backplane, the channels share a common ground. Applications requiring channel-to-channel isolation should utilize the TC-HAI081 series.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
The Shift to Flexible IO Modules in Modern Industrial Automation

The Shift to Flexible IO Modules in Modern Industrial Automation

Traditional control systems rely on dedicated Input Output (IO) cards for industrial automation. Each conventional module processes a single signal type, such as Digital Input (DI), Digital Output (DO), Analog Input (AI), or Analog Output (AO). A standard 16-channel card accepts only one specific channel type across all ports. This inflexible hardware design often creates severe engineering bottlenecks during project execution. Engineers frequently must install entirely new cards to accommodate a single extra sensor. Consequently, late design changes increase control cabinet space requirements and drive up project costs.

Read more
DCS Commissioning Steps in Industrial Automation Projects

DCS Commissioning Steps in Industrial Automation Projects

Commissioning a Distributed Control System (DCS) represents a crucial milestone when deploying modern process automation infrastructure. Field engineers must execute systematic verification steps to transition complex control hardware from static installation to dynamic plant control. Proper commissioning ensures that controllers, I/O modules, network switches, and HMI software operate in strict compliance with engineering design specifications before introducing live process fluids.

Read more
PLC and DCS Control System Spares Strategy: Engineering Guidelines

PLC and DCS Control System Spares Strategy: Engineering Guidelines

Modern factory automation relies on high-speed fiber optic backbones to link distributed control systems across noise-intensive industrial environments. Unlike copper wiring, optical fibers transmit data via light pulses, making them completely immune to electromagnetic interference (EMI). Field engineers must master optical cable joining and fusion splicing techniques to guarantee low-loss data transmission across critical Programmable Logic Controller (PLC) and Distributed Control System (DCS) nodes.

Read more