Skip to content

What are you looking for?


You may also like

Schneider Electric Modicon M580 Redundant Processor Module | BMEH586040Schneider Electric Modicon M580 Redundant Processor Module | BMEH586040Schneider Electric Modicon M580 Redundant Processor Module | BMEH586040
Schneider Electric Modicon M580 Redundant Processor Module | BMEH586040
Schneider Electric Modicon M580 Redundant Processor Module | BMEH586040
Schneider Electric Modicon M580 Redundant Processor Module | BMEH586040

Schneider Electric Modicon M580 Redundant Processor Module | BMEH586040


Only 10 left - Selling fast

PRODUCT SKU : BMEH586040

PRODUCT TYPE : Processor Module

PRODUCT VENDOR : Schneider


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Schneider Electric BMEH586040 stands as a premium-tier redundant processor within the Modicon M580 ePAC family. This module anchors high-availability automation architectures by providing seamless Hot Standby (HSBY) synchronization via a dedicated Ethernet port. It handles massive data throughput and complex process control checks, supporting integrated HART, Motion Control, and SSI encoder protocols. We supply this processor as 100% brand new, original hardware to ensure your mission-critical infrastructure operates with zero unplanned downtime.

Technical Specifications

The BMEH586040 utilizes a high-capacity memory architecture and rapid instruction execution to manage large-scale distributed I/O networks.

  • Processor Type: Redundant (Hot Standby)

  • Instruction Speed: 60 Kinst/ms (65% Boolean, 35% Fixed Arithmetic) / 40 Kinst/ms (100% Boolean)

  • Integrated RAM: 64 MB (Program and Data) / 4096 kB (HSBY Data) / 10 kB (System Memory)

  • Data Storage: 4 GB Expandable Flash

  • Integrated Ports: 1x Ethernet Service Port, 2x Ethernet Device Network, 1x Ethernet HSBY Port, 1x USB Mini-B

  • Network Capacity: Supports 31 Remote I/O Stations and 64 Distributed Equipment units

  • Communication Slots: Supports 6 Ethernet modules and 24 AS-Interface modules

  • Communication Services: RIO Scanner, DIO Scanner

  • Power Consumption: 295 mA at 24 V DC

  • Reliability: 600,000 Hours MTBF

Engineering Advantages

  • Instantaneous Failover Synchronization: The dedicated 100/1000 Mbps HSBY port links the primary and standby processors. This link mirrors 4096 kB of critical data every scan cycle, allowing the standby unit to assume control in milliseconds without interrupting the process flow or losing variable states.

  • Massive Network Scalability: The processor manages up to 31 remote I/O stations, including X80 and Quantum drops. This high-density capacity allows engineers to centralize control of geographically dispersed field devices into a single, redundant M580 pair.

  • Cybersecure Industrial Design: As an ePAC, the BMEH586040 utilizes native Ethernet throughout the backplane. It incorporates advanced security features to prevent unauthorized port access and ensures the integrity of the communication between the CPU and its 64 distributed devices.

  • Sophisticated Motion and Process Support: This module natively processes SSI encoder feedback and HART data. This integration eliminates the need for external gateways, reducing the physical footprint in the control cabinet and simplifying the software configuration in Unity Pro or Control Expert.

  • Robust Hardware for Extreme Racks: Despite its high 60 Kinst/ms processing speed, the module maintains a low 295 mA current draw. This efficiency prevents heat buildup in high-density racks, while the 600,000-hour MTBF rating guarantees performance in 24/7 continuous manufacturing environments.

FAQs

  • Can the BMEH586040 synchronize with a different M580 model?

    No. A Hot Standby pair requires two identical processors. Both units must be BMEH586040 models running the same firmware version to ensure the memory mapping and HSBY data synchronization remain perfectly aligned.

  • What is the purpose of the 4GB expandable Flash?

    The 4GB Flash provides high-capacity storage for historical data logging, recipe management, and project documentation directly on the CPU. This ensures your critical system files stay with the hardware, facilitating faster disaster recovery.

  • How does the processor handle mixed I/O drops?

    The BMEH586040 supports 31 stations and can manage 2 racks per drop for both X80 and legacy Quantum I/O. This flexibility allows you to modernize your control system without replacing existing, functional Quantum field wiring.

  • Does this unit come in original Schneider packaging?

    Yes. We sell only 100% Brand New original stock. Each BMEH586040 arrives in its original factory box with the manufacturer’s seal, serial number, and full documentation.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Proper wire labeling forms the cornerstone of reliable control system installation and long-term maintenance. In complex industrial automation environments, technicians terminate thousands of conductor ends inside control panels, marshalling racks, and field junction boxes. Ferrules serve as individual tube-shaped sleeve markers slipped onto conductors before final termination. While technicians historically relied on pre-printed individual letter rings, modern control panel builders utilize automated ferrule printing machines. These thermal-transfer printers generate durable, single-sleeve heat-shrink tags directly matching approved wiring schematics, significantly accelerating cabinet assembly workflows.

Read more
Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Marshalling cabinets serve as the crucial connection hub between field instruments and centralized processing units. In large DCS and PLC control system architectures, hundreds of multipair field cables run from local junction boxes to the central instrument equipment room. The marshalling cabinet houses field terminal blocks, surge arresters, intrinsic safety isolation barriers, and interposing relays. By segregating field field-wiring terminations from sensitive processor hardware, engineers protect expensive controller backplanes from high-voltage transients. Consequently, this modular separation dramatically streamlines maintenance workflows and simplifies system expansion.

Read more
Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Successful control system deployment begins with thoroughly reviewing manufacturer technical documentation. Controllers from major brands like Allen-Bradley, Siemens, and Schneider Electric feature unique terminal layouts. Engineers must verify voltage requirements before connecting power cables to prevent catastrophic equipment damage. Standard line connections require strict adherence to regional electrical codes and proper wire color coding. Furthermore, panel builders should always establish a robust low-impedance ground connection using at least 16-AWG copper conductor tied directly to the main plant grounding grid.

Read more