Product Details

Configured for AC-to-DC power conversion and system rail bus distribution in Yokogawa control systems, the Yokogawa PS35*A (PS35 Power Supply Module) provides direct physical/electrical execution.

Hardware Specifications

Parameter Specification
Model PS35*A
Brand Yokogawa
Origin Japan
Module Type Power Supply Module
Input Voltage AC Power Line Input
Output Voltage Regulated DC Bus Output
Mounting DIN Rail or Panel Mount
Operating Temp 0 to 50 deg C
Power Consumption Self-consumption internal power losses during conversion

Channel Isolation & Loop Power Infrastructure

The PS35*A power supply module incorporates internal galvanic isolation barriers between primary AC line connections, DC system buses, and protective ground earth. Galvanic decoupling prevents line transients and electrical noise from contaminating internal logic circuits and field loops, preserving signal resolution across attached 4-20 mA HART loop protocol transmitters and analog I/O modules.

Frequently Asked Questions

Q: How does electrical isolation inside the PS35*A protect downstream controller hardware?

A: Isolation transformer stages decouple the primary AC input line from the internal DC output rails, blocking common-mode noise and high-voltage surges from damaging controller backplanes.

Q: What mounting configurations support the physical installation of the PS35*A module?

A: The module supports direct DIN rail mounting or panel faceplate attachment depending on the base cabinet layout and carrier frame specification.

Field Installation Guidelines

Mount the PS35*A module securely onto the designated DIN rail track or cabinet panel baseplate. Verify that protective earth ground wiring is solidly bolted to the chassis ground terminal prior to applying primary AC power. Route incoming AC power connections in separate conduit runs away from low-voltage DC signals and 4-20 mA instrumentation lines to mitigate electromagnetic interference.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Instrumentation Control Systems in Modern Industrial Automation

Understanding Instrumentation Control Systems in Modern Industrial Automation

An instrumentation control system (ICS) serves as the central nervous system of modern manufacturing plants and processing facilities. Engineers classify these setups as Electrical, Electronic, or Programmable Electronic Systems (E/E/PES). In practice, an ICS bridges the physical world of industrial machinery with digital decision-making tools. Therefore, understanding its architecture is essential for anyone working in factory automation, process control, or plant safety.

Read more
Mastering Electrical Grounding Fundamentals in Industrial Automation and Control Systems

Mastering Electrical Grounding Fundamentals in Industrial Automation and Control Systems

Electrical grounding is a complex engineering discipline. It requires deep knowledge of soil composition and conductor materials. National Electrical Code (NEC) Article 250 outlines these requirements clearly. Many engineers confuse grounding, earthing, and bonding. Grounding connects circuits to a common reference point. Earthing specifically links equipment directly to the planet. Bonding permanently joins metallic parts to ensure electrical continuity.

Read more
Architectural Blueprint of Industrial Automation and Control Systems (IACS): Standards, Safety, and Remote Operations

Architectural Blueprint of Industrial Automation and Control Systems (IACS): Standards, Safety, and Remote Operations

According to IEC 62443, Industrial Automation and Control Systems (IACS) integrate personnel, hardware, and software. These components collectively influence the safety and reliability of any industrial process. Modern control systems allow extensive remote monitoring and operation. However, enabling remote capabilities introduces complex cybersecurity challenges. Therefore, facility operators must evaluate system functions carefully before expanding connectivity.

Read more