Skip to content

What are you looking for?


You may also like

ProSoft ILX34-MBS485 | Modbus Serial Communication ModuleProSoft ILX34-MBS485 | Modbus Serial Communication ModuleProSoft ILX34-MBS485 | Modbus Serial Communication Module
ProSoft ILX34-MBS485 | Modbus Serial Communication Module
ProSoft ILX34-MBS485 | Modbus Serial Communication Module
ProSoft ILX34-MBS485 | Modbus Serial Communication Module

ProSoft ILX34-MBS485 | Modbus Serial Communication Module


Only 10 left - Selling fast

PRODUCT SKU : MV169E-MBS

PRODUCT TYPE : Communication Module

PRODUCT VENDOR : PROSOFT


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Module Functional Overview

The ILX34-MBS485 (Part Number: ILX34-MBS485) is a high-performance serial communication adapter designed to integrate Modbus RTU/ASCII connectivity into Allen-Bradley Point I/O and 1769-L1x CompactLogix systems. This module functions as a versatile gateway, allowing Master or Slave communication via RS-485. Its ultra-compact 12mm form factor makes it an ideal solution for high-density distributed I/O architectures where cabinet space is at a premium.

Mechanical and Environmental Specifications

Engineered for industrial resilience, the ILX34-MBS485 provides stable performance in high-vibration environments.

Specification Category Value / Rating
Operational Shock Resistance 30 g
Vibration Acceleration 5 m/s² (continuous)
Vibration Frequency Range 10 to 500 Hz
Module Width 12 mm (0.47 inches)
Module Height 56 mm (2.20 inches)
Module Depth 75.5 mm (2.97 inches)
Operating Temperature -20°C to 55°C (-4°F to 131°F)
Storage/Transport Temp -40°C to 85°C (-40°F to 185°F)
Atmospheric Humidity 95% (Non-condensing)

Operational Integration and Use Cases

The ILX34-MBS485 allows engineers to interface with a wide range of field devices including power meters, variable frequency drives (VFDs), and environmental sensors. Because it mounts directly onto the Point I/O backplane, it reduces the need for complex external gateways.

  • Application Scenario: Remote monitoring of solar inverters via RS-485 Modbus where the controller is an Allen-Bradley 1769-L18ER.

  • System Compatibility: Designed for use with 1734-TB and 1734-TBS mounting bases.

Technical Implementation FAQ

Is external power required for the RS-485 port?

No, the module draws its operational power directly from the Point I/O backplane. However, proper termination resistors should be applied at both ends of the RS-485 daisy chain for signal integrity.

How is the module configured within Studio 5000?

Integration is achieved through an Add-On Profile (AOP) or a generic module profile. ProSoft provides specific configuration tools to define Modbus commands, slave IDs, and register mapping without complex ladder programming.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Dynamic Data Exchange (DDE) in Industrial Automation

Understanding Dynamic Data Exchange (DDE) in Industrial Automation

Dynamic Data Exchange (DDE) remains a vital legacy protocol for industrial communication. Originally for general computing, it now bridges the gap between factory floor data and enterprise reporting. This enduring method provides a foundational link for integrating real-time software layers in modern industrial automation.

Read more
Master FIFO and LIFO Sequences for Advanced PLC Logic

Master FIFO and LIFO Sequences for Advanced PLC Logic

In industrial automation, managing data flow is as critical as hardware control. This guide explores how FIFO and LIFO sequential logic can optimize your control systems. Master these essential tools to build more efficient sorting, inventory tracking, and data management workflows for any modern factory.

Read more
Power Cables vs. Signal Cables: Essential Guidelines for Industrial Automation

Power Cables vs. Signal Cables: Essential Guidelines for Industrial Automation

In industrial automation, distinguishing between power and signal cabling is vital. While power cables deliver energy to machinery, signal cables transmit critical data to control systems. This guide explores their technical differences and explains why proper isolation is the key to a reliable, interference-free factory automation network.

Read more