Product Description

The GE Fanuc VersaMax IC200BEM002 is a PROFIBUS-DP slave communication module designed to integrate VersaMax PLC systems into PROFIBUS networks. It supports automatic baud rate detection, multiple network topologies, and provides reliable communication for distributed I/O applications. With robust memory allocation and diagnostic indicators, this module ensures stable and efficient data exchange across industrial networks.

Technical Specifications

  • Manufacturer: GE Fanuc

  • Model / Part Number: IC200BEM002

  • Product Line: VersaMax

  • Product Type: Communication Module

  • Weight: 0.50 lbs (0.23 kg)

  • Network Protocol: PROFIBUS-DP Slave

  • Network Data Rate: 9.6 Kbaud to 12 Mbaud

  • Baud Rate Detection: Automatic

  • Number of Stations: 32 without repeaters, up to 125 with repeaters

  • I/O Data Capacity: 384 bytes

  • Connector Type: 9-pin D-sub connector

  • Network Topology: Linear bus, terminated at both ends

  • Transmission Media: Shielded twisted pair cable

  • Current Rating: 460 mA

  • Voltage Rating: 5 VDC

  • Input Impedance: 135–165 Ω

  • Mounting Format: DIN rail

  • Indicators: Power LED and Communication (COM) LED

Application Scenarios

The IC200BEM002 is ideal for distributed automation systems requiring PROFIBUS connectivity. It is commonly used in factory automation, process control, and machine monitoring where reliable communication between multiple stations is essential.

FAQ

Q: How many stations can be connected?  A: Up to 32 stations without repeaters, and up to 125 with repeaters.

Q: Does the module support automatic baud rate detection?  A: Yes, it automatically detects baud rates from 9.6 Kbaud to 12 Mbaud.

Q: What type of connector is used?  A: A 9-pin D-sub connector is provided for PROFIBUS network connections.

Comparison with Similar Models

  • IC200BEM001: Supports fewer stations, optimized for smaller networks.

  • IC200BEM010: Enhanced memory and diagnostics for larger installations. The IC200BEM002 offers a balanced solution with automatic baud rate detection and robust station support.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more