Skip to content

What are you looking for?


You may also like

GE Fanuc VersaMax IC200BEM002 | PROFIBUS-DP Slave Communication ModuleGE Fanuc VersaMax IC200BEM002 | PROFIBUS-DP Slave Communication ModuleGE Fanuc VersaMax IC200BEM002 | PROFIBUS-DP Slave Communication Module
GE Fanuc VersaMax IC200BEM002 | PROFIBUS-DP Slave Communication Module
GE Fanuc VersaMax IC200BEM002 | PROFIBUS-DP Slave Communication Module
GE Fanuc VersaMax IC200BEM002 | PROFIBUS-DP Slave Communication Module

GE Fanuc VersaMax IC200BEM002 | PROFIBUS-DP Slave Communication Module


Only 10 left - Selling fast

PRODUCT SKU : IC200BEM002

PRODUCT TYPE : Communication Module

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The GE Fanuc VersaMax IC200BEM002 is a PROFIBUS-DP slave communication module designed to integrate VersaMax PLC systems into PROFIBUS networks. It supports automatic baud rate detection, multiple network topologies, and provides reliable communication for distributed I/O applications. With robust memory allocation and diagnostic indicators, this module ensures stable and efficient data exchange across industrial networks.

Technical Specifications

  • Manufacturer: GE Fanuc

  • Model / Part Number: IC200BEM002

  • Product Line: VersaMax

  • Product Type: Communication Module

  • Weight: 0.50 lbs (0.23 kg)

  • Network Protocol: PROFIBUS-DP Slave

  • Network Data Rate: 9.6 Kbaud to 12 Mbaud

  • Baud Rate Detection: Automatic

  • Number of Stations: 32 without repeaters, up to 125 with repeaters

  • I/O Data Capacity: 384 bytes

  • Connector Type: 9-pin D-sub connector

  • Network Topology: Linear bus, terminated at both ends

  • Transmission Media: Shielded twisted pair cable

  • Current Rating: 460 mA

  • Voltage Rating: 5 VDC

  • Input Impedance: 135–165 Ω

  • Mounting Format: DIN rail

  • Indicators: Power LED and Communication (COM) LED

Application Scenarios

The IC200BEM002 is ideal for distributed automation systems requiring PROFIBUS connectivity. It is commonly used in factory automation, process control, and machine monitoring where reliable communication between multiple stations is essential.

FAQ

Q: How many stations can be connected?  A: Up to 32 stations without repeaters, and up to 125 with repeaters.

Q: Does the module support automatic baud rate detection?  A: Yes, it automatically detects baud rates from 9.6 Kbaud to 12 Mbaud.

Q: What type of connector is used?  A: A 9-pin D-sub connector is provided for PROFIBUS network connections.

Comparison with Similar Models

  • IC200BEM001: Supports fewer stations, optimized for smaller networks.

  • IC200BEM010: Enhanced memory and diagnostics for larger installations. The IC200BEM002 offers a balanced solution with automatic baud rate detection and robust station support.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more