Skip to content

What are you looking for?


You may also like

P0973JM A4H124-24TX Foxboro Ethernet SwitchP0973JM A4H124-24TX Foxboro Ethernet SwitchP0973JM A4H124-24TX Foxboro Ethernet Switch
P0973JM A4H124-24TX Foxboro Ethernet Switch
P0973JM A4H124-24TX Foxboro Ethernet Switch
P0973JM A4H124-24TX Foxboro Ethernet Switch

P0973JM A4H124-24TX Foxboro Ethernet Switch


Only 10 left - Selling fast

PRODUCT SKU : P0973JM A4H124-24TX

PRODUCT TYPE : Ethernet Switches

PRODUCT VENDOR : Foxboro


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for high-density copper Ethernet switching and packet distribution within Foxboro industrial control network architectures, the Foxboro P0973JM A4H124-24TX (P0973JM Ethernet Switch) provides direct physical/electrical execution. It operates as a 24-port 10/100Base-T managed switch platform designed to maintain deterministic data communication across distributed automation nodes and supervisory host systems.

Suffix Breakdown & Model Matrix

  • P0973JM: Foxboro specific system catalog and hardware identification suffix defining proprietary assembly, custom mounting adaptation, and logistics tracking.
  • A4H124-24TX: Original OEM platform designation representing the 24-port copper Ethernet switch core configuration.

Hardware Specifications

Parameter Specification
Model P0973JM (A4H124-24TX)
Brand Foxboro / Extreme Networks
Origin Consult Factory
Weight Standard Industrial Rackmount Chassis Class
Dimensions Standard 19-inch 1U Rackmount Form Factor
Operating Temp 0 deg C to 50 deg C
Power Consumption Standard AC/DC Internal Redundant Power Rails
Number of Ports 24 ports for 10/100Base-T Ethernet
Switching Capacity Industrial Wire-Speed Performance
VLAN Support Standard IEEE 802.1Q VLAN Tagging
MAC Address Table Size Standard Enterprise Table Architecture

4-20 mA HART Loop Protocol and Isolation

The integration of industrial networking hardware into distributed control systems mandates strict physical segregation between high-speed packet exchanges and sensitive analog measurement infrastructures. While handling multi-port Ethernet data traffic, this switch provides robust isolation barriers that prevent electromagnetic interference from bridging Ethernet backbones and adjacent 4-20 mA HART loop protocol lines or FOUNDATION Fieldbus / Profibus PA connectivity loops residing on nearby termination assemblies. Grounding and galvanic protection profiles safeguard controller ports from common-mode voltage transients.

Frequently Asked Questions

Q: Does the P0973JM switch support redundant power supply inputs for high availability?

A: Yes, it is engineered with dual power input support to ensure uninterrupted network operations during cabinet power supply failure scenarios.

Q: What type of physical media connections are supported on the 24 ports?

A: The switch features 24 copper ports configured for standard 10/100Base-T Ethernet connectivity over RJ45 interfaces.

Q: Are the Ethernet ports capable of auto-negotiation for speed and duplex modes?

A: Yes, all ports support automatic speed detection and full/half-duplex operation modes to match connected field devices and controllers.

Field Installation Guidelines

Mount the switch securely within a standard 19-inch industrial equipment rack, ensuring sufficient front and rear clearance for natural convection airflow and thermal management. Verify that all network cables are properly routed through dedicated cable management channels away from high-voltage power lines. Connect the chassis ground directly to the cabinet ground bus using a low-impedance copper conductor prior to energizing the power supplies.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Demystifying the DDE Protocol in Legacy Industrial Automation Systems

Demystifying the DDE Protocol in Legacy Industrial Automation Systems

Modern control systems rely heavily on seamless interprocess communication to exchange operational data between software programs. Microsoft first introduced the Dynamic Data Exchange (DDE) protocol in 1987 to enable real-time data sharing. In factory automation, DDE served as an early bridge between control software and Windows desktop applications. Therefore, understanding DDE mechanics provides crucial insights into how legacy industrial networks established software-level connectivity.

Read more
Demystifying CPU Communication Ports in Siemens PLC Architectures

Demystifying CPU Communication Ports in Siemens PLC Architectures

Industrial automation relies heavily on robust data exchange between devices. Without seamless connectivity, field instruments, network switches, human-machine interfaces, and programmable logic controllers cannot coordinate effectively. Therefore, understanding the various CPU communication ports available in Siemens hardware ensures efficient factory automation design and seamless system integration.

Read more
Mastering the Siemens PLC Scan Cycle: How the CPU Executes Automation Programs

Mastering the Siemens PLC Scan Cycle: How the CPU Executes Automation Programs

Industrial automation relies heavily on programmable logic controllers (PLCs) to manage complex manufacturing processes. Many engineers dive straight into programming without mastering the underlying architecture. However, understanding how a PLC CPU executes a program ensures reliable system design. Therefore, mastering the scan cycle optimizes both performance and troubleshooting in modern control systems.

Read more