Skip to content

What are you looking for?


You may also like

P0916KP-0B | Foxboro | Input ModuleP0916KP-0B | Foxboro | Input ModuleP0916KP-0B | Foxboro | Input Module
P0916KP-0B | Foxboro | Input Module
P0916KP-0B | Foxboro | Input Module
P0916KP-0B | Foxboro | Input Module

P0916KP-0B | Foxboro | Input Module


Only 10 left - Selling fast

PRODUCT SKU : P0916KP-0B

PRODUCT TYPE : Input Modules

PRODUCT VENDOR : Foxboro


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for discrete input signal acquisition within Foxboro distributed control architectures, the Foxboro P0916KP-0B (P0916KP-0B Input Module) provides direct physical/electrical execution for 16 communication input channels utilizing 32 screw termination points.

Hardware Specifications

Parameter Specification
Model P0916KP-0B
Brand Foxboro
Origin Standard Industrial Manufacturing
Weight 0.56 lbs (0.25 kg)
Dimensions Standard Modular Form Factor
Operating Temp -20 deg C to +70 deg C
Power Consumption Backplane-supplied low-voltage DC logic
Input Channels 16 communication inputs
Termination Points 32 screw terminations
Signal Interface 37-pin male D-sub connection

4-20 mA HART Loop Protocol and Channel Isolation

Operating within Foxboro DCS environments, the input module interfaces with field sensors while maintaining channel-to-channel isolation to prevent common-mode voltage interference across measurement and control loops. The internal signal conditioning circuitry supports standard 4-20 mA HART loop protocol parameters or discrete digital states, applying internal filtering stages to suppress electrical noise. Cold junction compensation (CJC) or differential scaling is utilized locally where required to guarantee signal conversion accuracy before transmission across the internal system backplane.

Frequently Asked Questions

Q: Does the P0916KP-0B module support hot-swapping under active system power?

A: Hot-swap capability is governed by the specific chassis power distribution and node configuration of the host Foxboro system. Generally, field screw terminal blocks can remain wired during module extraction, but system configuration rules must be verified prior to removal to prevent communication faults.

Q: How should field wiring shields be terminated at the 32-point screw termination block?

A: Field signal cable shields must be landed directly to the dedicated instrument earth ground bar or designated shield terminals on the termination assembly, avoiding single-point ground loops to maintain electromagnetic noise immunity.

Field Installation Guidelines

  • Ensure all control power and field loop power are completely isolated and locked out before installing or removing the module.
  • Inspect the 37-pin male connector and terminal block pins for alignment and freedom from contamination prior to assembly.
  • Secure all terminal screws and module retention fasteners to specified torque limits to withstand industrial plant vibration environments.
  • Verify correct channel addressing and configuration parameters prior to system startup.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mastering the Siemens PLC Scan Cycle: How the CPU Executes Automation Programs

Mastering the Siemens PLC Scan Cycle: How the CPU Executes Automation Programs

Industrial automation relies heavily on programmable logic controllers (PLCs) to manage complex manufacturing processes. Many engineers dive straight into programming without mastering the underlying architecture. However, understanding how a PLC CPU executes a program ensures reliable system design. Therefore, mastering the scan cycle optimizes both performance and troubleshooting in modern control systems.

Read more
How to Connect to Siemens S7 PLCs: 5 Essential Communication Methods

How to Connect to Siemens S7 PLCs: 5 Essential Communication Methods

Establishing a reliable hardware link between a programming terminal and a Siemens SIMATIC controller is essential for engineering workflows. Field engineers rely on distinct physical layers, ranging from legacy serial connections to high-speed Industrial Ethernet protocols. Modern factory automation environments prioritize fast data transfer and seamless driver integration. Selecting the correct connection method simplifies program downloads, online monitoring, and system troubleshooting in complex control systems.

Read more
Will PLCs Become Obsolete? The Future of Control Systems in Industry 4.0

Will PLCs Become Obsolete? The Future of Control Systems in Industry 4.0

Modern manufacturing is undergoing a rapid technological transformation driven by Industry 4.0 innovations. Technologies like Artificial Intelligence (AI), Machine Learning (ML), and the Industrial Internet of Things (IIoT) are dominating discussions across the factory automation sector. Consequently, many engineers wonder if these advanced digital tools will eventually replace traditional Programmable Logic Controllers (PLCs). However, evaluating the core physics of industrial operations reveals a very different reality for control systems.

Read more