PRODUCT SKU : MC-TSIA12 51303932-478

PRODUCT TYPE : Serial Interface Module

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Honeywell MC-TSIA12 (Part Number: 51303932-478) serves as a specialized Serial Interface Field Termination Assembly (FTA) optimized for Modbus RTU communication. This module bridges Honeywell Input/Output Processors (IOP) with external Modbus-compatible devices, ensuring seamless data exchange across the industrial network. We offer this unit as 100% Brand New and Original, providing a pristine hardware foundation for high-accuracy telemetry and control integration.

Technical Specifications

Parameter Specification Details
Model Number MC-TSIA12
Part Number 51303932-478
Protocol Modbus RTU
Baud Rate 19.2 kbps
Channel Count 2 Channels per IOP
Max Transmission Distance 300 Meters
Common Mode Voltage 250 V RMS (Continuous)
Power Dissipation 1.4 Watts (Maximum)
Operating Temperature -40°C to +70°C
Terminal Options DB25 or Compression Terminals

Engineering Advantages

  • Neutralizes Electrical Interference: The MC-TSIA12 maintains a continuous 250 V RMS common-mode voltage rating. This high isolation barrier protects the central control logic from ground loops and electrical surges common in expansive field networks.

  • Extends Operating Range: Built for the edge, this FTA operates flawlessly from -40°C to +70°C. It withstands the thermal stress of non-climate-controlled marshalling cabinets in extreme environments, such as desert oil fields or arctic processing plants.

  • Streamlines Modbus Integration: The module hardware supports a fixed 19.2 kbps baud rate and an 8-bit data format with parity. This standardization simplifies the configuration of Modbus RTU networks, ensuring rapid handshake and stable data polling with flow meters, power analyzers, and PLCs.

  • Flexible Termination Architecture: Engineers can choose between DB25 connectors for rapid plug-and-play setup or compression terminals for secure, vibration-resistant field wiring. This flexibility solves the physical installation challenges of tight cabinet spaces.

  • Minimizes Thermal Load: With a maximum power dissipation of only 1.4 watts, the MC-TSIA12 reduces the heat signature within the I/O rack. This low-power design prevents localized overheating and extends the MTBF (Mean Time Between Failure) of adjacent components.

FAQs

  • Can I use the MC-TSIA12 for redundant serial links? This specific model does not support redundancy. For applications requiring fault-tolerant serial communication, you must implement dual-path logic at the processor level or utilize a different FTA model designed for redundant pair operation.

  • What is the maximum cable length for a stable Modbus connection? The MC-TSIA12 supports a maximum distance of 300 meters. To ensure signal integrity at this range, use high-quality shielded twisted-pair (STP) cabling to minimize electromagnetic interference.

  • Is this unit a "New Old Stock" (NOS) or factory-fresh item? We guarantee the MC-TSIA12 is 100% Brand New and Original. It ships in its original Honeywell factory packaging with intact seals, ensuring it has never been deployed in a field environment.

  • Does it support protocols other than Modbus RTU? The 51303932-478 is specifically engineered for Modbus RTU communication. Using this module for other serial protocols may result in communication failures or incorrect data parsing within the Honeywell IOP environment.

 

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more