Skip to content

What are you looking for?


You may also like

MC-PRHM01 Honeywell Remote Hardened Low Level MultiplexerMC-PRHM01 Honeywell Remote Hardened Low Level MultiplexerMC-PRHM01 Honeywell Remote Hardened Low Level Multiplexer
MC-PRHM01 Honeywell Remote Hardened Low Level Multiplexer
MC-PRHM01 Honeywell Remote Hardened Low Level Multiplexer
MC-PRHM01 Honeywell Remote Hardened Low Level Multiplexer

MC-PRHM01 Honeywell Remote Hardened Low Level Multiplexer


Only 10 left - Selling fast

PRODUCT SKU : MC-PRHM01 51404109-175

PRODUCT TYPE : Multiplexer Modules

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Honeywell MC-PRHM01, also cataloged as the MC-PRHM01 51404109-175 Remote Hardened Low Level Multiplexer, operates as a dedicated hardware component for low-level analog signal acquisition and channel scanning within Honeywell Process Manager (PM/APM/HPM) I/O subsystems.

Hardware Specifications

Parameter Specification
Model MC-PRHM01 (51404109-175)
Brand Honeywell
Origin USA
Weight 0.52 kg
Dimensions 30 mm x 314 mm x 278 mm
Operating Temp -40 to 70 deg C
Power Consumption Powered via I/O link backplane supply
Module Type Remote Hardened Low Level Multiplexer
Signal Processing Low-level analog signal (TC, mV) multiplexing
Subsystem Compatibility Honeywell High Performance Process Manager (HPM) / APM
Mounting Standard Process Manager I/O File / Chassis

Cold Junction Compensation and Channel-to-Channel Isolation

The MC-PRHM01 low-level multiplexer conditions microvolt-level inputs from thermocouples and millivolt transducers before routing multiplexed data across the I/O link bus. Precision internal cold junction compensation (CJC) circuits dynamically correct thermal electromotive force (EMF) offsets at terminal junction points. Integrated channel-to-channel isolation safeguards individual measurement paths against common-mode electrical noise, ground potential differentials, and external field interference typical of remote process control environments.

Frequently Asked Questions

Q: Does removing or inserting the MC-PRHM01 module during active node operation disturb adjacent I/O modules on the same link?

A: Live extraction requires adhering to slot isolation rules; removing the module drops signal acquisition for connected low-level channels but does not disrupt backplane communication across unassociated I/O file slots.

Q: How does the module handle cold junction compensation reference updates across wide ambient thermal changes?

A: On-board solid-state RTD sensors monitor terminal block temperatures continuously, providing immediate compensation coefficient updates to the analog-to-digital processing sub-circuit.

Field Installation Guidelines

  1. Inspect the card edge gold fingers and rear connector pins of the MC-PRHM01 module for physical distortion or debris before insertion.
  2. Align the module circuit board with the top and bottom card guide tracks of the designated I/O chassis slot.
  3. Push the module firmly into the slot until the backplane connectors seat completely and locking latches engage.
  4. Ensure thermocouple lead shields are grounded at a single point on the field termination assembly to prevent ground loops.
  5. Secure all field termination assembly (FTA) cable connectors to the front faceplate to ensure signal shield continuity and vibration resistance.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Siemens PLC Memory Cards: MMC, SMC, and SD Solutions in Industrial Automation

Understanding Siemens PLC Memory Cards: MMC, SMC, and SD Solutions in Industrial Automation

Memory management plays a pivotal role in maintaining control system reliability across modern manufacturing plants. Industrial control systems rely on specialized memory cards to store project logic, firmware updates, and retentive system data. Siemens uses several memory architectures, including Micro Memory Cards (MMC) and SIMATIC Memory Cards (SMC). Engineers must understand these hardware variations to ensure zero data loss and minimize downtime during maintenance routines.

Read more
Redefining Control Systems: The Rise of Flexible I/O Modules in Industrial Automation

Redefining Control Systems: The Rise of Flexible I/O Modules in Industrial Automation

Conventional input-output architectures often limit engineering agility and inflate long-term inventory costs. Today, Flexible Input/Output Modules (FIOM) are transforming how control system engineers design, commission, and maintain automation infrastructure. By allowing individual channel software configuration, FIOM technology bridges the gap between rigid hardware design and dynamic plant requirements.

Read more
Understanding Modern SCADA Systems: Architecture, Communication Topologies, and Industrial Applications

Understanding Modern SCADA Systems: Architecture, Communication Topologies, and Industrial Applications

Supervisory Control and Data Acquisition (SCADA) systems form the digital backbone of modern industrial automation. They collect critical field data, transmit signals across vast distances, and empower plant operators with real-time process visibility. Across modern infrastructures, SCADA solutions streamline centralized control and maintain continuous operational uptime.

Read more