Skip to content

What are you looking for?


You may also like

MC-PAOX03 51309152-175 | Honeywell Experion PKS Analog Output 8-Point ProcessorMC-PAOX03 51309152-175 | Honeywell Experion PKS Analog Output 8-Point ProcessorMC-PAOX03 51309152-175 | Honeywell Experion PKS Analog Output 8-Point Processor
MC-PAOX03 51309152-175 | Honeywell Experion PKS Analog Output 8-Point Processor
MC-PAOX03 51309152-175 | Honeywell Experion PKS Analog Output 8-Point Processor
MC-PAOX03 51309152-175 | Honeywell Experion PKS Analog Output 8-Point Processor

MC-PAOX03 51309152-175 | Honeywell Experion PKS Analog Output 8-Point Processor


Only 10 left - Selling fast

PRODUCT SKU : MC-PAOX03 51309512-175

PRODUCT TYPE : Analog Output Module

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Honeywell MC-PAOX03 (51309152-175) serves as a high-precision, 8-channel Analog Output (AO) processor designed for critical control loops within the Honeywell Experion PKS and TDC 3000 ecosystems. This 100% Brand New and original module converts digital control commands into 0.1-21.4 mA current signals to drive final control elements like valves and actuators. Featuring full conformal coating and integrated redundancy support, this processor ensures deterministic control and maximum uptime in aggressive industrial atmospheres.

Technical Specifications

  • Manufacturer: Honeywell

  • Model Number: MC-PAOX03

  • Part Number: 51309152-175 (CE Compliant)

  • Number of Channels: 8

  • Output Current Range: 0.1 to 21.4 mA

  • Maximum Current Output: 26 mA

  • Resolution: ± 0.05%

  • Calibrated Accuracy: ± 0.35% (at 25°C)

  • Maximum Resistive Load: 750 Ω @ 22 mA

  • Output Ripple: 100 mV peak-to-peak (at power line frequency)

  • Surge Capability: Meets ANSI/IEEE C37.90.1-1978 standards

  • Environmental Protection: Conformal Coating (Resistant to chemical gases/humidity)

  • Redundancy: Supports full redundancy with electrically isolated outputs

  • Shipping Weight: 2.0 kg

Engineering Advantages

  • Corrosion-Resistant Conformal Coating: Honeywell applies a specialized plastic protective layer to every MC-PAOX03 assembly. This coating shields the sensitive surface-mount components from humidity and corrosive chemical gases, solving the problem of premature hardware failure in harsh environments like refineries or paper mills.

  • Hardware-Level Redundancy: The module utilizes a Field Replaceable Relay Switch on the FTA to manage redundancy. This method electrically isolates the outputs, ensuring that a standby module takes over the control loop instantly without signal bumps or process interruption.

  • Precision Loop Accuracy: The ± 0.05% resolution ensures ultra-fine control over valve positioning. This precision minimizes process oscillation, which directly optimizes raw material consumption and energy efficiency in high-stakes chemical processes.

  • High-Load Driving Capacity: Capable of driving up to a 750 Ω resistive load at 22 mA, the MC-PAOX03 powers signals over long cable runs without voltage drop issues. This feature eliminates the need for external signal boosters in large-scale plant layouts.

  • Industrial Surge Hardening: The circuitry adheres to ANSI/IEEE C37.90.1-1978 surge withstand standards. This internal protection prevents damage from electrical transients and switching surges common in heavy industrial power grids.

FAQs

  • What is the difference between part number 51309152-175 and 51304672-150?

    The 51309152-175 is the CE-compliant version required for European markets and modern safety standards, while the 51304672-150 is the non-CE compliant legacy version. Both share the same functional MC-PAOX03 8-point architecture.

  • How does the redundancy bias function work on this module?

    The redundancy bias ensures a deterministic state during module transitions. In a redundant pair, the system maintains a specific electrical bias to allow for a "bumpless" transfer of the 4-20mA signal if the primary processor fails.

  • Is this module suitable for high-humidity installations?

    Yes. The conformal coating and the 10-90% non-condensing humidity rating make it ideal for tropical or high-moisture environments. The coating prevents "silver whiskering" and dendritic growth that often cause short circuits on non-protected boards.

  • How do I confirm this unit is 100% Brand New?

    We supply each MC-PAOX03 in its original factory-sealed packaging. Every unit carries the original Honeywell serial number and CE-compliance labels, guaranteeing you receive a zero-hour, un-energized component for your critical infrastructure.

 

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more