Skip to content

What are you looking for?


You may also like

IS200TDBTH6A Discrete Input/Output Terminal Board | GEIS200TDBTH6A Discrete Input/Output Terminal Board | GEIS200TDBTH6A Discrete Input/Output Terminal Board | GE
IS200TDBTH6A Discrete Input/Output Terminal Board | GE
IS200TDBTH6A Discrete Input/Output Terminal Board | GE
IS200TDBTH6A Discrete Input/Output Terminal Board | GE

IS200TDBTH6A Discrete Input/Output Terminal Board | GE


Only 10 left - Selling fast

PRODUCT SKU : IS200TDBTH6A

PRODUCT TYPE : Digital I/O Cards

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for discrete signal management and relay-based control within Mark VIe architectures, the GE IS200TDBTH6A (IS200TDBTH6A Discrete Input/Output Terminal Board) provides direct physical and electrical execution of multi-channel I/O signal routing.

Hardware Specifications

Parameter Specification
Model IS200TDBTH6A
Brand General Electric
Origin USA
Weight Standard terminal board assembly
Dimensions 17.8 cm x 33.02 cm
Operating Temp -30 deg C to 65 deg C
Power Consumption +5 VDC (Control), 24 VDC (I/O)
Digital I/O 24 channels
Relay Channels 12

Profinet / EtherNet/IP Deterministic Networks

The IS200TDBTH6A serves as a critical interface node within the Mark VIe control platform, enabling deterministic signal processing for discrete field instrumentation. The board integrates hardware-based input filtering to mitigate noise and provides a rejection capability of 12 V RMS for incoming AC voltage interference. Backplane bus communication velocity is optimized to ensure that state changes across the 24 digital channels and 12 relay outputs are processed within specified scan cycles. Firmware flash compatibility is managed via the host I/O pack, ensuring that logic transitions remain synchronized with system timing requirements. The board supports I/O density scaling through its compact surface-mount architecture, allowing for high-density relay control without compromising signal integrity.

Frequently Asked Questions

Q: Is the IS200TDBTH6A board hot-swappable while the system is energized?

A: No. Replacement of this terminal board must be performed with the control rack de-energized to prevent electrical shorts or backplane communication bus corruption.

Q: Are the 12 relay channels isolated from the 24 digital I/O channels?

A: The board design requires correct field wiring and shielding practices to ensure isolation between high-power relay switching circuits and low-power digital signal inputs.

Field Installation Guidelines

  1. Mounting: Secure the board using the designated mounting points within the control cabinet. Ensure adequate clearance from high-voltage cabling to prevent inductive noise on the discrete signal paths.
  2. Wiring: Terminate all digital I/O and relay connections to the terminal blocks. Use shielded cabling for long cable runs, and terminate shields at the cabinet grounding bus to suppress common-mode interference.
  3. Relay Loading: Verify that the current and voltage ratings of the external loads connected to the 12 relay channels do not exceed the board's rated switching capacity. Use suppression diodes when switching inductive loads to extend relay contact life.
  4. Environment: Maintain the ambient operating temperature between -30 deg C and 65 deg C. Ensure cabinet airflow is sufficient to dissipate heat generated during high-duty relay switching operations.
  5. Verification: Prior to commissioning, confirm the logic mapping for all 24 digital channels and 12 relay outputs via the Mark VIe configuration software. Perform a continuity check on all field wiring before energizing the I/O circuits.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Transforming Shop Floor Data into Actionable Insights: A Deep Dive into MES

Transforming Shop Floor Data into Actionable Insights: A Deep Dive into MES

Manufacturing Execution Systems serve as the digital backbone of modern factory floors. Positioned at Level 3 of the ISA-95 automation pyramid, MES links enterprise resource planning with real-time shop floor control systems. Today, industrial operators rely on MES software to bridge operational strategy with physical production execution.

Read more
Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Industrial Ethernet forms the backbone of factory automation. Selecting the right switch architecture determines system uptime, data throughput, and OT cyber resilience. This technical guide evaluates managed vs. unmanaged switches, analyzing operational differences, security controls, and selection criteria.
Read more
Hot Standby vs. Cold Standby Redundancy in Industrial Automation

Hot Standby vs. Cold Standby Redundancy in Industrial Automation

System availability determines process safety and productivity in industrial automation. Control engineers deploy redundancy to eliminate single points of failure. This technical guide evaluates Hot Standby vs. Cold Standby architectures, comparing failover speeds, memory sync, cost trade-offs, and field selection criteria.

Read more