PRODUCT SKU : IC695CPU315

PRODUCT TYPE : Controller CPU Module

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The IC695CPU315 is a powerful CPU module from the GE Fanuc PACSystems RX3i series, engineered for high-speed execution and versatile communication in industrial automation. With dual integrated serial ports, extensive memory capacity, and support for multiple fieldbus protocols, this controller is designed to handle complex control tasks across distributed systems.

Technical Specifications

  • Manufacturer: GE Fanuc

  • Product Line: PACSystems RX3i

  • Part Number: IC695CPU315

  • Product Type: Central Processing Unit (CPU) Module

  • Lifecycle Status: Active

  • Processor Speed: 1 GHz

  • Boolean Execution Speed: 0.047 ms/K

  • User Logic Memory: 20 MB SRAM/Flash

  • Memory Storage: SRAM and Flash with battery backup

  • Real-Time Clock: Battery-backed

  • Dynamic Data Backup: Battery backup only

  • I/O Capacity: 32K discrete points; 32K analog points

  • Built-in Serial Ports: One RS-485 and one RS-232 (supports SNP, Serial I/O, Modbus Master/Slave)

  • USB-A 2.0 Master Port: Not available

  • Local Rack Support: Up to 8 racks

  • Communications Options: Serial, Genius, CMX (Reflective Memory), Ethernet

  • Supported Networks: Ethernet (PROFINET, EGD, Modbus TCP Server/Client), Genius, PROFIBUS DP, DeviceNet

  • Programming Software: Proficy Machine Edition Logic Developer Professional v5.6 or higher

  • Supported Languages: Ladder Logic, Function Block Diagram, Structured Text, C

  • Internal Power Usage: 1750 mA @ 3.3 VDC; 1200 mA @ 5 VDC

  • Backplane Support: Universal Backplane only; PCI bus

  • Slot Occupancy: 2 slots

  • Shipping Weight: 3 kg

Application Scenarios

  • Large-scale automation requiring fast execution and high memory capacity

  • Distributed control systems with multiple communication protocols

  • Industrial environments needing robust CPU performance and flexible I/O handling

FAQ

Q: How many local racks can be supported?  A: Up to 8 local racks.

Q: What communication protocols are available?  A: Ethernet (PROFINET, EGD, Modbus TCP), Genius, PROFIBUS DP, DeviceNet, and CMX Reflective Memory.

Q: What programming languages are supported?  A: Ladder Logic, Function Block Diagram, Structured Text, and C.

Q: Does the CPU include a real-time clock?  A: Yes, it is battery-backed for reliability.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Proper wire labeling forms the cornerstone of reliable control system installation and long-term maintenance. In complex industrial automation environments, technicians terminate thousands of conductor ends inside control panels, marshalling racks, and field junction boxes. Ferrules serve as individual tube-shaped sleeve markers slipped onto conductors before final termination. While technicians historically relied on pre-printed individual letter rings, modern control panel builders utilize automated ferrule printing machines. These thermal-transfer printers generate durable, single-sleeve heat-shrink tags directly matching approved wiring schematics, significantly accelerating cabinet assembly workflows.

Read more
Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Marshalling cabinets serve as the crucial connection hub between field instruments and centralized processing units. In large DCS and PLC control system architectures, hundreds of multipair field cables run from local junction boxes to the central instrument equipment room. The marshalling cabinet houses field terminal blocks, surge arresters, intrinsic safety isolation barriers, and interposing relays. By segregating field field-wiring terminations from sensitive processor hardware, engineers protect expensive controller backplanes from high-voltage transients. Consequently, this modular separation dramatically streamlines maintenance workflows and simplifies system expansion.

Read more
Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Successful control system deployment begins with thoroughly reviewing manufacturer technical documentation. Controllers from major brands like Allen-Bradley, Siemens, and Schneider Electric feature unique terminal layouts. Engineers must verify voltage requirements before connecting power cables to prevent catastrophic equipment damage. Standard line connections require strict adherence to regional electrical codes and proper wire color coding. Furthermore, panel builders should always establish a robust low-impedance ground connection using at least 16-AWG copper conductor tied directly to the main plant grounding grid.

Read more